- Ana Sayfa
- Prysmian
- Power Cables
- Protodur® Installation Cables
- H03VV-F / H03VVH2-F
H03VV-F / H03VVH2-F
Structure
Multi-core, finely stranded, copper conductor, PROTODUR® (PVC) insulated, PROTODUR® (PVC) outer sheathed, flexible cables.
Technical Information
– Manufactured according to TS EN 50525-2-11.
– Permissible Operating Temperature: 70 ºC
– Maximum Short Circuit Temperature: 160 ºC
– Conductor Structure: Flexible
– FR (Flame Resistance) Test: IEC 60332-1-2
– CPR (Construction Materials Directive) Test: EN 60332-1-2
– Test Voltage (AC): 1.5 kV
Areas of Use
They are used as mobile connection cables in closed and dry places where mechanical stresses are low.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Aynı Markalı Diğer Ürünlerimiz
Structure
Multi-core, multi-wire, copper conductor, special synthetic insulated, galvanized flat steel wire armored, special synthetic outer sheathed, flame retardant, halogen-free and non-smoking energy cables.
Technical Information
– Manufactured in accordance with TS IEC 60502-1.
– Permissible operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– Conductor Structure: Rigid
– LS (Low Smoke) Test: IEC 61034 -1/2
– Burning Droplet Test: IEC 60332-1-3
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-1-2 and IEC 60332-3-24 Cat.C
– Galvanized Flat Steel Wire Armored
Areas of Use
These cables are resistant to mechanical external effects thanks to the armor consisting of galvanized flat steel wires on them. They are used in places where mandatory safety precautions are taken against fire.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Single or multi-core, single or multi-wire, copper conductor, three or four-core, special synthetic insulated, galvanized round steel wire armored, special synthetic outer sheathed, flame retardant, halogen-free and non-smoking energy cables. (Aluminum in single-core cables.)
Technical Information
– Manufactured in accordance with TS IEC 60502-1.
– Permissible operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– Conductor Structure: Rigid
– LS (Low Smoke) Test: IEC 61034 -1/2
– Burning Droplet Test: IEC 60332-1-3
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-1-2 and IEC 60332-3-24 Cat.C
– CPR (Construction Materials Directive) Test: EN 60332-1-2
– Galvanized Round Steel Wire Armored
Areas of Use
These cables are resistant to mechanical external effects thanks to the armor consisting of galvanized round steel wires on them. They are used in places where there are mandatory safety precautions against fire.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Single or multi-core, single or multi-wire copper conductor, special synthetic insulation, special synthetic outer sheath, flame retardant, halogen-free cables that do not create dense smoke during fire.
Technical Information
– Manufactured in accordance with TS HD 604 S1 5G.
– Permissible operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– Conductor Structure: Rigid
– LS (Low Smoke) Test: IEC 61034 -1/2
– Burning Droplet Test: IEC 60332-1-3
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-1-2 and IEC 60332-3-24 Cat.C
– CPR (Construction Materials Directive) Test: EN 50399
Areas of Use
These cables are used in indoor and outdoor areas such as schools, hospitals, meetings and shopping malls where there are mandatory safety precautions against fire.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Single-core, single-wire, multi-wire or fine multi-wire copper conductor, special synthetic insulation, flame retardant and halogen-free energy cables.
Technical Information
– Manufactured in accordance with TS EN 50525-3-31.
– Permissible operating temperature: 70 ºC
– Maximum Short Circuit Temperature: 160 ºC
– Conductor Structure: Flexible
– LS (Low Smoke) Test: IEC 61034 -1/2
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-1-2
– CPR (Construction Materials Directive) Test: EN 60332-1-2
Areas of Use
They are used as lighting and installation cables in dry spaces, switchgear facilities, distribution systems, and businesses.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file, or send it to the address you want via e-mail.
Structure
Single-core, multi-wire, copper conductor, PROTOTHEN®–X (XLPE) insulation with very low dielectric losses, special inner and outer semiconductor layers that homogenize the electrical field, copper screen with a section suitable for high short-circuit currents and specially reinforced, water-swellable tape layer, aluminum protective sheath and polyethylene outer sheath high voltage energy cables. The screen is watertight in longitudinal and radial directions. If desired, longitudinal watertightness can be provided in the conductor.
Technical Information
– They are manufactured according to TS 10382 IEC 60840.
– Permissible Operating Temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC (Short circuit time t ≤ 5 sec.)
– Conductor Structure: Rigid
– Test Voltage (AC): 2.5Uo (30 min.)
Areas of Use
These cables are located underground, in concrete channels and / or PVC-PE pipes, in places where aerial high voltage lines cannot enter city centers due to safety, health and visual pollution, and they connect energy production / distribution places transformer centers to national / international distribution networks.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Three-core, multi-wire, copper conductor, PROTOTHEN®-X (XLPE) insulation with very low dielectric losses, special inner and outer semi-conductor layers that homogenize the electrical field, specially added copper screen with a suitable cross-section against high short circuit currents, flat galvanized steel wire armor and galvanized steel holding tape, LSOH outer sheathed medium voltage energy cables.
Technical Information
-They are manufactured according to TS IEC 60502-2.
– Permissible Operating Temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC (Short circuit time t ≤ 5 sec.)
– Conductor Structure: Rigid
– FR (Flame Resistance) Test: IEC 60332-1-2
– Test Voltage (AC): 3.5Uo
– Galvanized Flat Steel Wire Armored
Areas of Use
These cables, which have very low electrical losses compared to their counterparts, are used in electrical energy supply of large residential and industrial areas with large short circuit currents and in networks where load increases are expected, outdoors, in cable ducts, indoors and underground. When specially produced, they are used in fresh and salt water.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Medium voltage energy cables with single core, multi-wire, copper conductor, PROTOTHEN®-X (XLPE) insulation with very low dielectric losses, special inner and outer semiconductor layers that homogenize the electrical field, specially added copper screen against high short circuit currents with a suitable cross-section, LSOH outer sheath.
Technical Information
-They are manufactured according to TS IEC 60502-2.
– Permissible Operating Temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC (Short circuit time t ≤ 5 sec.)
– Conductor Structure: Rigid
– FR (Flame Resistance) Test: IEC 60332-1-2
– Test Voltage (AC): 3.5Uo
Areas of Use
These cables, which have very low electrical losses compared to their counterparts, are used in electrical energy supply of residential and industrial areas where short circuit currents are high and in networks where load increases are expected, outdoors, in cable ducts, indoors and underground. When specially produced, they are used in fresh and salt water.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Three-core, multi-wire, copper conductor, very low dielectric losses
PROTOTHEN®-X (XLPE) insulation, special inner and outer semi-conductor layers that homogenize the electrical field, suitable cross-section against high short-circuit currents
and specially added copper screen, flat galvanized steel wire armor and galvanized steel holding tape, halogen-free, does not create a dense smoke layer during fire and LSOH outer sheathed medium voltage energy cables
Technical Information
These cables are manufactured in accordance with TS IEC 60502-2.
– Permissible operating temperature: 90 ºC
– Permissible short circuit temperature: 250 ºC
(For short circuit time t ≤ 5 sec.)
They are tested in accordance with the following standards:
LS (Low Smoke) Test: IEC 61034-1/2
Burning Droplet Test: IEC 60332-1-3
HF (Halogen Free) Test: IEC 60754-1/2
FR (Flame Resistance) Test: IEC 60332-1-2 and IEC 60332-3-24 Cat.C
Places of Use
These cables, which have very low electrical losses compared to their counterparts, are used in electrical energy supply of residential and industrial areas where short circuit currents are high and in networks where load increases are expected, outdoors, in cable ducts and indoors.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Three-core, multi-wire, copper conductor, PROTOTHEN®-X (XLPE) insulation with very low dielectric losses, special inner and outer semi-conductor layers that homogenize the electrical field, specially added copper screen with a suitable cross-section against high short circuit currents, flat galvanized steel wire armor and galvanized steel holding tape, LSOH outer sheathed medium voltage energy cables.
Technical Information
-They are manufactured according to TS IEC 60502-2.
– Permissible Operating Temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC (Short circuit time t ≤ 5 sec.)
– Conductor Structure: Rigid
– FR (Flame Resistance) Test: IEC 60332-1-2
– Test Voltage (AC): 3.5Uo
– Galvanized Flat Steel Wire Armored
Areas of Use
These cables, which have very low electrical losses compared to their counterparts, are used in electrical energy supply of large residential and industrial areas with large short circuit currents and in networks where load increases are expected, outdoors, in cable ducts, indoors and underground. When specially produced, they are used in fresh and salt water.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Medium voltage energy cables with single core, multi-wire, copper conductor, PROTOTHEN®-X (XLPE) insulation with very low dielectric losses, special inner and outer semiconductor layers that homogenize the electrical field, specially added copper screen against high short circuit currents with a suitable cross-section, LSOH outer sheath.
Technical Information
-They are manufactured according to TS IEC 60502-2.
– Permissible Operating Temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC (Short circuit time t ≤ 5 sec.)
– Conductor Structure: Rigid
– FR (Flame Resistance) Test: IEC 60332-1-2
– Test Voltage (AC): 3.5Uo
Areas of Use
These cables, which have very low electrical losses compared to their counterparts, are used in electrical energy supply of residential and industrial areas where short circuit currents are high and in networks where load increases are expected, outdoors, in cable ducts, indoors and underground. When specially produced, they are used in fresh and salt water.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Multi-core, multi-wire, copper conductor, PROTOTHEN®-X (XLPE) insulated, galvanized flat steel wire armor, cross-holding steel tape, PROTODUR® (PVC) outer sheathed energy cables.
Technical Information
-Manufactured according to TS IEC 60502-1.
– Permissible Operating Temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC (Short circuit time t ≤ 5 sec.)
– Conductor Structure: Rigid
– FR (Flame Resistance) Test: IEC 60332-1-2
– CPR (Construction Materials Directive) Test: EN 60332-1-2
– Test Voltage (AC): 3.5 kV
– Galvanized Flat Steel Wire Armored
Areas of Use
These cables are very resistant to mechanical external effects thanks to the armor made of flat steel wires on them. They are suitable for heavy operating, laying and assembly conditions. They are used underground and in fresh and salt water when specially produced.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Single or multi-core, single or multi-wire, copper conductor PROTOTHEN®-X (XLPE) insulated, galvanized round steel wire armored, PROTODUR® (PVC) outer sheathed energy cables. (Aluminum in single-core cables.)
Technical Information
-They are manufactured according to TS IEC 60502-1.
– Permissible Operating Temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC (Short circuit time t ≤ 5 sec.)
– Conductor Structure: Rigid
– FR (Flame Resistance) Test: IEC 60332-1-2
– CPR (Construction Materials Directive) Test: EN 60332-1-2
– Test Voltage (AC): 3.5 kV
– Galvanized Round Steel Wire Armored
Areas of Use
These cables are very resistant to mechanical external effects thanks to the armor made of galvanized round steel wires on them. They are suitable for heavy operating, laying and assembly conditions. They are used underground and in fresh and salt water when specially produced.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.