Single-core, single-wire or fine multi-wire, copper conductor, silicone rubber insulated, flexible cables resistant to high ambient temperatures -40 ºC, +180 ºC operating temperature.
Technical Information
– Manufactured in accordance with TSE K 332.
– Minimum allowed operating temperature: -40 ºC
– Maximum allowed operating temperature: 180 ºC
– Maximum Short Circuit Temperature: 350 ºC
– FR (Flame Resistance) Test: IEC 60332-1-2
– Conductor Structure: Flexible
Areas of Use
They are used in dry, humid and wet places where there is high ambient temperature and low mechanical stress, as internal and external flexible connection cables at continuous 180 ºC temperature and short-term 350 ºC temperature.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Areas of Use
As power and control cables;
In devices and machines that need to work during a fire (emergency elevators, fire water systems, etc.)
In ventilation systems connected to the fire alarm system
In lighting fire escape routes
In emergency power supplies
In places where human life, valuable materials and equipment need to be protected
In places where there is electromagnetic interference and interference
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Areas of Use
As power and control cables;
In devices and machines that need to work during a fire (emergency elevators, fire water systems, etc.)
In ventilation systems connected to the fire alarm system
In lighting fire escape routes
In emergency power supplies
In places where human life, valuable materials and equipment need to be protected
In places where there is electromagnetic interference and interference
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Areas of Use
As power and control cable;
In devices and machines that need to work during a fire (emergency elevators, fire water systems, etc.)
In ventilation systems connected to a fire alarm system
In lighting fire escape routes
In emergency power sources
In places where human life, valuable materials and equipment need to be protected
Notes
* BASED STANDARD: VDE 0276-604 HD 604 S1
**PASSED PH 180 CLASS IN VDE CERTIFICATION
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Areas of Use
As power and control cables;
In devices and machines that need to work during a fire (emergency elevators, fire water systems, etc.)
In ventilation systems connected to the fire alarm system
In lighting fire escape routes
In emergency power sources
In places where human life, valuable materials and equipment need to be protected
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Single-core, tinned finely stranded copper conductor; EPR insulation, PCP rubber outer sheath.
Technical Information
– Manufactured in accordance with VDE 0250-602.
– Permissible operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 200 ºC
– Conductor Structure: Flexible
– FR (Flame Resistance) Test: IEC 60332-1-2 and IEC 60332-3-24 Cat.C
Areas of Use
Used in trains and buses, in continuously operating installations, in pipes and closed installation channels and in mobile connections. Also used in short circuit and grounding connections.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Tinned, very fine and multi-wire, copper conductor, PROTOLON® (EPR) insulated, rubber inner sheath, synthetic yarn sock braid, tear-resistant, chloroprene-rubber outer sheathed crane control cables.
Technical Information
– Manufactured in accordance with TSE K 371.
– Permissible operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– Conductor Structure: Flexible
– FR (Flame Resistance) Test: IEC 60332-1-2 and IEC 60332-3-24 Cat.C
– Maximum Movement Speed: 120 m/min
– Continuous Tensile Force: 20 N/mm2
Areas of Use
They are used in dry, damp and wet areas, in places where there are external, heavy mechanical strains, in cranes and similar work machines with a maximum winding speed of 120 m/min.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Tinned, finely stranded electrolytic copper conductor, PROTOLON® (EPR) insulation, electrical field homogenizing inner and outer rubber semiconductor layer, PROTOFIRM® outer sheathed oil and flame resistant medium voltage tail cables.
Technical Information
– Manufactured in accordance with TSE K 371.
– Permissible operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 200 ºC
– Conductor Structure: Flexible
– FR (Flame Resistance) Test: IEC 60332-1-2
– Suitable for use in oily environments.
– Continuous Tensile Strength: 15 N/mm2
Areas of Use
They are used in dry, damp and wet areas, outside, open mines, in businesses where resistance to friction is required, inside tunnels, in quarries, in places where there are heavy mechanical strains.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Tinned, finely stranded copper conductor, PROTOLON® (EPR) insulation, electrical field homogenizing rubber inner and outer semi-conducting layer, rubber inner sheath, synthetic yarn braid, PROTOFIRM® outer sheath oil and flame resistant medium voltage cables.
Technical Information
– Manufactured in accordance with TSE K 371.
– Permissible operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 200 ºC
– FR (Flame Resistance) Test: IEC 60332-1-2
– Suitable for use in oily environments.
– Maximum Movement Speed: 120 m/min
– Continuous Tensile Force: 15 N/mm2
Areas of Use
They are used as tail cables and feeder cables in dry, damp and wet areas, in places with external, heavy mechanical strain, in mines, in conveyor and transfer roller belt systems, in cranes and similar work machines.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Tinned, finely stranded, electrolytic copper conductor, PROTOLON® (EPR) insulation, rubber filler element, rubber inner sheath and tear-resistant PROTOFIRM® outer sheathed tail cables.
Technical Information
– Manufactured in accordance with TSE K 371.
– Permissible operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 200 ºC
– Conductor Structure: Flexible
– FR (Flame Resistance) Test: IEC 60332-1-2 and IEC 60332-3-24 Cat.C
– Maximum Movement Speed: 60 m/min
– Continuous Tensile Strength: 15 N/mm2
Areas of Use
They are used in dry, damp and wet areas, in places with external, heavy mechanical stresses, in mines, in conveyor and conveyor roller belt systems, in cranes and similar work machines as tail cables and feeder cables.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Construction
Inner conductor: copper wire, bare, diameter 0.41 mm
Insulation: Foam-PE, diameter 1.9 mm
Outer conductor: Al-PET-Al foil + copper braid, tinned, diameter 2.5 mm
Sheath: FRNC or PVC, diameter 3.1mm
Printing: DRAKA – 0.41/1.9 AF – 75 Ω ± 1%
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Cable structure
Conductor: Cu wire, solid, bare, diameter 0.6 mm
Insulation: Foamed PE, natural color, diameter 2.8 mm
Overall shield: Aluminum-coated plastic film, lengthways with tinned CU braid on top, diameter 3.4 mm
Protective jacket: FRNC or PVC, diameter 4.5 mm
Jacket color: Green, RAL 6018
Printing:
for FRNC: DRAKA – 0.6/2.8 AF – 75 Ω ± 1% – HDTV FRNC
for PVC: DRAKA – 0.6/2.8 AF – 75 Ω ± 1% – HDTV
Product description and details in PDF icon click details görüntüleyebilir, dosyayı indirebilir veya istediğiniz address mail yolu ile ulaştırabilirsiniz.
Construction
Inner conductor: solid copper wire, bare, diameter 0.6 mm
Insulation: PE, diameter 3.7 mm
Outer conductor: copper braid, bare, optical coverage 84 %, diameter 4.3 mm
Sheath: PVC, diameter 6.0 mm green, RAL 6018
Printing: DRAKA COMTEQ – 0.6/3.7 AF – 75 ± 1%
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Construction
Inner conductor: solid copper wire, bare, diameter 0.8 mm
Insulation: Foam-PE, diameter 3.7 mm
Outer conductor: Al-PET-Al-foil under tinned copper braid,
diameter 4.5mm
Sheath: FRNC, FRNC-C or PVC, diameter 5.9 mm green, RAL 6018
Printing :
FRNC – DRAKA 0.8/3.7 AF – 75 Ω ± 1% – HDTV 5GHz – FRNC” + batch no. and meter marking
FRNC-C – DRAKA 0.8/3.7 AF – 75 Ω ± 1% – HDTV 5GHz – FRNC-C” + batch no. and meter marking
PVC – DRAKA 0.8/3.7 AF – 75 Ω ± 1% – HDTV 5GHz” + batch no. and meter marking
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Construction
Inner conductor: stranded copper wire, diameter 0.8 mm
Insulation: Foam-PE, diameter 3.7 mm
Outer conductor: 2xCu-braid, tinned 4.6 mm
Sheath: DMC FLEX PVC diameter 6.0 mm black, RAL 9005
Printing: DRAKA 0.8L/3.7Dz – 75 Ω +- 1% – HIGHFLEX HDTV 5GHz + batch no. + meter marking
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Multi-core, multi-wire copper conductor, special XLPE insulation, special synthetic outer sheath, flame retardant, halogen-free, rubber filled, copper wire braided, ship cables that continue their function for 180 minutes under fire.
Technical Information
– Manufactured in accordance with IEC 60092-350/375/376.
– Minimum allowed operating temperature: -15 ºC
– Maximum allowed operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– LS (Low Smoke) Test: IEC 61034 -1/2
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-3-22 Cat.A
– FE (Current Conduction) Test: IEC 60331-21
Areas of Use
They are used as communication, signal and control cables in fixed installations in places where mechanical and electrical protection is required on ships and all kinds of marine vehicles.