Areas of Use
It is used as a fixed installation cable in ships and all floating vehicles. The shielding layer forms a protection layer against external electromagnetic interference. Thanks to its halogen-free and flame-retardant structure, it provides a non-corrosive and vision-free environment in case of fire.
For product technical specifications and details, you can click on the PDF icon to view the details, download the file or send it to the address you want via e-mail.
Areas of Use
Used as communication and control cables in the electronic systems of ships and all floating vehicles. The shielding layer protects the transmitted signal against external electromagnetic interference. Thanks to its halogen-free and flame-retardant structure, it provides a non-corrosive and vision-free environment in case of fire.
For product technical specifications and details, you can click on the PDF icon to view the details, download the file or send it to the address you want via e-mail.
Dust Cover: Aluminum, T = 1.5 (type one), T = 1.0 (type two)
Matrix: Aluminum, T = 1.5 (type one), T = 1.0 (type two)
Adapter Plate: Without
Splice Tray: Without
Panel: Aluminum
Lock: Without
Adapter: MTP (rear side), Duplex LC (front side)
Dimension: H×W×D = 34mm × 131mm × 121.5mm (type one) – H×W×D = 35mm × 141.5mm × 166.5mm (type two)
Surface Finish: Power coating
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Slot Width 11-12mm
Wide Compression Range
Single and Double Cable Compression Versions
FT, AI, VA
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Multi-core, fine multi-wire, copper conductor, silicone rubber insulated, flexible cables with operating temperatures of -40 ºC, +180 ºC.
Technical Information
– Manufactured in accordance with VDE 0250e.
– Minimum allowed operating temperature: -40 ºC
– Maximum allowed operating temperature: 180 ºC
– Maximum Short Circuit Temperature: 350 ºC
– Conductor Structure: Flexible
Areas of Use
They are used as internal and external flexible connection cables at continuous 180 ºC and short-term 350 ºC temperatures in dry, humid and wet locations where there is high ambient temperature and low mechanical stress.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Areas of Use
0.6/1 kV XLPE insulated halogen-free, galvanized steel tape armored cables are suitable for heavy operating conditions where protection against external effects and mechanical strength are important. They are used in fire-sensitive places and spaces such as high-rise buildings, shopping malls, hospitals, schools where people are very densely located.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Areas of Use
0.6/1 kV XLPE insulated, galvanized steel tape armored cables are suitable for heavy operating conditions where protection against external effects and mechanical strength are important. They are resistant to sudden and short-term operating temperature increases.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Multi-core, single or multi-wire copper conductor, special synthetic insulation, concentric copper screen, special synthetic outer sheath, flame retardant, halogen-free, non-smoking cables during fire.
Technical Information
– Manufactured in accordance with TS HD 604 S1 5G.
– Permissible operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– Conductor Structure: Rigid
– LS (Low Smoke) Test: IEC 61034 -1/2
– Burning Droplet Test: IEC 60332-1-3
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-1-2 and IEC 60332-3-24 Cat.C
– CPR (Construction Materials Directive) Test: EN 50399
Areas of Use
These cables are used in indoor and outdoor areas such as schools, hospitals, meetings and shopping malls where there are mandatory safety precautions against fire.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Multi-core, single or multi-wire copper conductor, special flame-resistant separator layer, special synthetic insulation, concentric copper conductor, special synthetic outer sheath, flame-retardant, halogen-free, non-smoking and 180 minutes flame-resistant energy and control cables according to IEC 60331-21.
Technical Information
– Manufactured in accordance with TS HD 604 S1 5G.
– Permissible operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– Conductor Structure: Rigid
– LS (Low Smoke) Test: IEC 61034 -1/2
– Burning Droplet Test: IEC 60332-1-3
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-1-2 and IEC 60332-3-24 Cat.C
– FE (Current Conduction) Test: IEC 60331-21
Areas of Use
These cables are used in indoor and outdoor areas such as schools, hospitals, meetings and shopping malls where there are mandatory safety precautions against fire.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Multi-core, single or multi-wire copper conductor, special flame-resistant separator layer, special synthetic insulation, concentric copper conductor, special synthetic outer sheath, flame-retardant, halogen-free, non-smoking and 180 minutes flame-resistant energy and control cables according to IEC 60331-21.
Technical Information
– Manufactured in accordance with TS HD 604 S1 5G.
– Permissible operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– Conductor Structure: Rigid
– LS (Low Smoke) Test: IEC 61034 -1/2
– Burning Droplet Test: IEC 60332-1-3
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-1-2 and IEC 60332-3-24 Cat.C
– FE (Current Conduction) Test: IEC 60331-21
Areas of Use
These cables are used in indoor and outdoor areas such as schools, hospitals, meetings and shopping malls where there are mandatory safety precautions against fire.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Areas of Use
0.6/1 kV XLPE insulated, concentric copper tape conductor cables are generally used underground. The concentric conductor allows monitoring of external impacts coming to the cable by connecting to a protection switch and/or relay.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Areas of Use
0.6/1 kV halogen-free, flame-retardant single or multi-core energy cables should be used in fire-sensitive areas and spaces such as high-rise buildings, shopping malls, hospitals, schools, where people are very densely located.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file, or send it to the address you want via e-mail.