LiYY
Structure
A cable core is formed by twisting the cores or pairs coated with PVC insulation in accordance with VDE 0207 Part 4 YI3, with a thickness that will meet the electrical properties, on the conductor formed by multiple twisting of copper wires.
After wrapping a polyester tape (optional) with holding and protective properties on this core, a gray sheath in accordance with VDE 0207 Part 5 YM1 is covered on it.
The outer sheath thickness shall be in accordance with ÜBM-03-BK-022
Technical Information
Temperature in fixed conditions: -30 °C, +70 °C
Temperature in mobile conditions: -5 °C, +50 °C
Areas of Use
Used in indoor automation systems, electronic control systems, dry environments, as signal and information communication cable.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Aynı Markalı Diğer Ürünlerimiz
Structure
The center tube contains the optical fibers and waterproof material, forming the cable core. Glass yarn material is applied around the cable core to increase dielectric strength. Black colored PE sheath is applied on the glass yarn material.
Technical Information
– Temperature in fixed conditions: -25 °C, +70 °C
– Temperature in moving conditions: -10 °C, +50 °C
– Minimum Operating Temperature: -25 ºC
– Maximum Operating Temperature: 70 ºC
– Conductor Structure: Rigid
– Bending Radius: Min 15xD
– Lead-free
Areas of Use
These center tube, unarmored fiber optic cables are designed for use in ducts.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
The cable core is formed by bending thermoplastic tubes and sufficient number of elements (tubes or fillers) containing up to 12 single/multi mode optical fibers and waterproof material together with the fibers with the SZ method. The cable core is filled with filling material for longitudinal waterproofing. Glass yarn material is wrapped on the filled cable core for environmental reinforcement. Corrugated steel tape armor application is made, coated with copolymer material on both sides to protect the cable core from external factors. Black colored PE sheath is applied on the armor.
Technical Information
– Temperature in fixed conditions: -30 °C, +70 °C
– Temperature in moving conditions: -10 °C, +50 °C
– Minimum Operating Temperature: -30 ºC
– Maximum Operating Temperature: 70 ºC
– Conductor Structure: Rigid
– Bending Radius: Min 15xD
– Lead-free
Areas of Use
These multi-tube, armored fiber optic cables are designed for direct burial or in ducts, and are external environment cables.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Single or multi-core, single or multi-wire copper conductor, special flame-resistant separator layer, special synthetic insulation, galvanized round steel wire armor, special synthetic outer sheath, flame-retardant, halogen-free, non-smoking during fire and continue to function for 180 minutes under flame according to IEC 60331-21. (Armor is aluminum in single-core cables.)
Technical Information
– They are manufactured in accordance with TS IEC 60502-1.
– Permissible operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– Conductor Structure: Rigid
– LS (Low Smoke) Test: IEC 61034 -1/2
– Burning Droplet Test: IEC 60332-1-3
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-1-2 and IEC 60332-3-24 Cat.C
– FE (Current Conduction) Test: IEC 60331-21
Areas of Use
These cables are used in indoor and outdoor areas such as schools, hospitals, meetings and shopping malls where there are mandatory safety precautions against fire.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Single or multi-core, single or multi-wire copper conductor, special flame-resistant separator layer, special synthetic insulation, galvanized round steel wire armor, special synthetic outer sheath, flame-retardant, halogen-free, non-smoking during fire and continue to function for 180 minutes under flame according to IEC 60331-21. (Armor is aluminum in single-core cables.)
Technical Information
– They are manufactured in accordance with TS IEC 60502-1.
– Permissible operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– Conductor Structure: Rigid
– LS (Low Smoke) Test: IEC 61034 -1/2
– Burning Droplet Test: IEC 60332-1-3
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-1-2 and IEC 60332-3-24 Cat.C
– FE (Current Conduction) Test: IEC 60331-21
Areas of Use
These cables are used in indoor and outdoor areas such as schools, hospitals, meetings and shopping malls where there are mandatory safety precautions against fire.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Single or multi-core, single or multi-wire copper conductor, special flame-resistant separator layer, special synthetic insulation, special synthetic outer sheath, flame-retardant, halogen-free, non-smoking and 180 minutes flame-resistant energy and control cables according to IEC 60331-21.
Technical Information
– Manufactured in accordance with TS HD 604 S1 5G.
– Permissible operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– Conductor Structure: Rigid
– LS (Low Smoke) Test: IEC 61034 -1/2
– Burning Droplet Test: IEC 60332-1-3
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-1-2 and IEC 60332-3-24 Cat.C
– FE (Current Conduction) Test: IEC 60331-21
Areas of Use
These cables are used in indoor and outdoor areas such as schools, hospitals, meetings and shopping malls where there are mandatory safety precautions against fire.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Multi-core, single or multi-wire copper conductor, special synthetic insulation, concentric copper screen, special synthetic outer sheath, flame retardant, halogen-free, non-smoking cables during fire.
Technical Information
– Manufactured in accordance with TS HD 604 S1 5G.
– Permissible operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– Conductor Structure: Rigid
– LS (Low Smoke) Test: IEC 61034 -1/2
– Burning Droplet Test: IEC 60332-1-3
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-1-2 and IEC 60332-3-24 Cat.C
– CPR (Construction Materials Directive) Test: EN 50399
Areas of Use
These cables are used in indoor and outdoor areas such as schools, hospitals, meetings and shopping malls where there are mandatory safety precautions against fire.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Single or multi-core, single or multi-wire copper conductor, special synthetic insulation, special synthetic outer sheath, flame retardant, halogen-free cables that do not create dense smoke during fire.
Technical Information
– Manufactured in accordance with TS HD 604 S1 5G.
– Permissible operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– Conductor Structure: Rigid
– LS (Low Smoke) Test: IEC 61034 -1/2
– Burning Droplet Test: IEC 60332-1-3
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-1-2 and IEC 60332-3-24 Cat.C
– CPR (Construction Materials Directive) Test: EN 50399
Areas of Use
These cables are used in indoor and outdoor areas such as schools, hospitals, meetings and shopping malls where there are mandatory safety precautions against fire.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Single-core, multi-wire, copper conductor, PROTOTHEN®–X (XLPE) insulation with very low dielectric losses, special inner and outer semiconductor layers that homogenize the electrical field, copper screen with a section suitable for high short-circuit currents and specially reinforced, water-swellable tape layer, aluminum protective sheath and polyethylene outer sheath high voltage energy cables. The screen is watertight in longitudinal and radial directions. If desired, longitudinal watertightness can be provided in the conductor.
Technical Information
– They are manufactured according to TS 10382 IEC 60840.
– Permissible Operating Temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC (Short circuit time t ≤ 5 sec.)
– Conductor Structure: Rigid
– Test Voltage (AC): 2.5Uo (30 min.)
Areas of Use
These cables are located underground, in concrete channels and / or PVC-PE pipes, in places where aerial high voltage lines cannot enter city centers due to safety, health and visual pollution, and they connect energy production / distribution places transformer centers to national / international distribution networks.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Medium voltage energy cables with single core, multi-wire, copper conductor, very low dielectric loss PROTOTHEN®-X (XLPE) insulation, special inner and outer semi-conductor layers that homogenize the electrical field, specially added copper screen against high short circuit currents, LSOH outer sheath.
Technical Information
– They are manufactured in accordance with TSE K 204 and based on IEC 60502-2.
– Permissible Operating Temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC (Short circuit time t ≤ 5 sec.)
– Conductor Structure: Rigid
– FR (Flame Resistance) Test: IEC 60332-1-2
– Test Voltage (AC): 3.5Uo
Areas of Use
These cables, which have very low electrical losses compared to their counterparts, are used in electrical energy supply of residential and industrial areas where short circuit currents are high and in networks where load increases are expected, outdoors, in cable ducts, indoors and underground. When specially produced, they are used in fresh and salt water.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Medium voltage energy cables with single core, multi-wire, copper conductor, PROTOTHEN®-X (XLPE) insulation with very low dielectric losses, special inner and outer semiconductor layers that homogenize the electrical field, specially added copper screen against high short circuit currents with a suitable cross-section, LSOH outer sheath.
Technical Information
-They are manufactured according to TS IEC 60502-2.
– Permissible Operating Temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC (Short circuit time t ≤ 5 sec.)
– Conductor Structure: Rigid
– FR (Flame Resistance) Test: IEC 60332-1-2
– Test Voltage (AC): 3.5Uo
Areas of Use
These cables, which have very low electrical losses compared to their counterparts, are used in electrical energy supply of residential and industrial areas where short circuit currents are high and in networks where load increases are expected, outdoors, in cable ducts, indoors and underground. When specially produced, they are used in fresh and salt water.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Three-core, multi-wire, copper conductor, very low dielectric losses
PROTOTHEN®-X (XLPE) insulation, special inner and outer semi-conductor layers that homogenize the electrical field, suitable cross-section against high short-circuit currents
and specially added copper screen, flat galvanized steel wire armor and galvanized steel holding tape, halogen-free, does not create a dense smoke layer during fire and LSOH outer sheathed medium voltage energy cables
Technical Information
These cables are manufactured in accordance with TS IEC 60502-2.
– Permissible operating temperature: 90 ºC
– Permissible short circuit temperature: 250 ºC
(For short circuit time t ≤ 5 sec.)
They are tested in accordance with the following standards:
LS (Low Smoke) Test: IEC 61034-1/2
Burning Droplet Test: IEC 60332-1-3
HF (Halogen Free) Test: IEC 60754-1/2
FR (Flame Resistance) Test: IEC 60332-1-2 and IEC 60332-3-24 Cat.C
Places of Use
These cables, which have very low electrical losses compared to their counterparts, are used in electrical energy supply of residential and industrial areas where short circuit currents are high and in networks where load increases are expected, outdoors, in cable ducts and indoors.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Medium voltage energy cables with single core, multi-wire, copper conductor, PROTOTHEN®-X (XLPE) insulation with very low dielectric losses, special inner and outer semiconductor layers that homogenize the electrical field, specially added copper screen against high short circuit currents with a suitable cross-section, LSOH outer sheath.
Technical Information
-They are manufactured according to TS IEC 60502-2.
– Permissible Operating Temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC (For short circuit time t ≤ 5 sec.)
– Conductor Structure: Rigid
– FR (Flame Resistance) Test: IEC 60332-1-2
– Test Voltage (AC): 3.5Uo
Areas of Use
These cables, which have much lower electrical losses than their counterparts, are used in electrical energy supply of residential and industrial areas with high short circuit currents and in networks where load increases are expected, outdoors, in cable ducts, indoors and underground. When specially produced, they are used in fresh and salt water.