- Ana Sayfa
- Prysmian
- Telecom Solutions (Low Current Cables)
- Fiber Optic Cable Accessories
- Wall Mounted Termination Boxes
- WM020-06 24F Internal & External Termination Box
WM020-06 24F Internal & External Termination Box
Features and Benefits
• Provides the termination of an optical cable of up to 24 fibres onto an
adapter panel. SC, FC, LC, E2000 and ST connectors can be accommodated.
• Supplied with 12 single circuit splice trays. The splice trays hinge upwards
to provide access to the adapter panel. The box can be supplied with splice
trays for either heat shrink or crimp splice protectors.
• Suitable for both internal and external use. The box is rated to IP55.
• The box has two cable entry ports and one exit port for up to 24 patchcords
or cables.
• Input cables of up to 16mm in diameter can be accommodated. Input cables
are secured and sealed into the box using heatshrink sleeves.
• Output patchcords or cables exit the box through a plastic cable gland. The
gland can be used to secure a 25mm corrugated tube. The corrugated tube
is sold separately in lengths required by the customer. Please refer to
addition items.
• Mechanical cable glands can be supplied instead of heat shrink glands.
These will be fitted by Prysmian depending on the cable diameter. Please
contact the sales desk for further information.
• Lockable to prevent unauthorised access.
• The unit is manufactured from UV resistant material for external use.
Technical Data
• Number of cable entries: 2 in, 24 out
• Maximum cable diameter (mm): 16.0
• Maximum Capacity: 48 splices, 24 terminations
• Maximum no. of customer feeds: 24
• Required space envelope (mm): (w) 270 x (h) 272 x (d) 100.
• Operating temperature: -20oC to + 50oC (5 to 95% RH)
• Sealing: IP55
• Material: –
• Cover: Polycarbonate
• Base: Polycarbonate
• Splice Trays: PC ABS
• Finish:-
• Cover: Grey RAL 7040
• Base: Grey RAL 7040
• Splice trays: Grey RAL 7035
• Testing:-
• Optical: Tested 1310nm,1550nm and 1625nm
• Dry heat: BS EN 60068-2-2 Test Bb
• Damp heat: IEC 60068-2-3: 1969
• Change of temperature: IEC 60068-2-14: 1984
• Vibration: IEC 60068-2-6: 1995
• Shock: IEC 60068-2-27: 1987
Aynı Markalı Diğer Ürünlerimiz
Structure
The cable core is formed by bending thermoplastic tubes containing up to 12 single/multi mode optical fibers and waterproof material together with the fibers and a sufficient number of elements (tubes or fillers) together with the SZ method. The cable core is filled with filling material for longitudinal waterproofing. Glass yarn material is wrapped on the filled cable core for environmental reinforcement. Black colored PE sheath is applied on the glass yarn material.
Technical Information
– Temperature in fixed conditions: -30 °C, +70 °C
– Temperature in moving conditions: -10 °C, +50 °C
– Minimum Operating Temperature: -30 ºC
– Maximum Operating Temperature: 70 ºC
– Conductor Structure: Rigid
– Bending Radius: Min 10xD
– Lead-free
Areas of Use
These multi-tube, dielectric fiber optic cables are external environment cables designed for use in channels.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
The center tube contains the optical fibers and waterproof material, forming the cable core. Glass yarn material is applied around the cable core to increase dielectric strength. Black colored PE sheath is applied on the glass yarn material.
Technical Information
– Temperature in fixed conditions: -25 °C, +70 °C
– Temperature in moving conditions: -10 °C, +50 °C
– Minimum Operating Temperature: -25 ºC
– Maximum Operating Temperature: 70 ºC
– Conductor Structure: Rigid
– Bending Radius: Min 15xD
– Lead-free
Areas of Use
These center tube, unarmored fiber optic cables are designed for use in ducts.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
The center tube contains the optical fibers and waterproof material, forming the cable core. Glass yarn material is applied around the cable core to increase dielectric strength. Black colored PE sheath is applied on the glass yarn material.
Technical Information
– Temperature in fixed conditions: -25 °C, +70 °C
– Temperature in moving conditions: -10 °C, +50 °C
– Minimum Operating Temperature: -25 ºC
– Maximum Operating Temperature: 70 ºC
– Conductor Structure: Rigid
– Bending Radius: Min 15xD
– Lead-free
Areas of Use
These center tube, unarmored fiber optic cables are designed for use in ducts.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
The center tube forms the cable core by containing optical fibers and waterproof material. To increase dielectric strength, glass yarn material is applied around the cable core. To protect the cable core from external factors, corrugated steel tape armor application is made with copolymer material on both sides. Black colored PE sheath is applied on the armor.
Technical Information
– Temperature in fixed conditions: -25 °C, +70 °C
– Temperature in moving conditions: -10 °C, +50 °C
– Minimum Operating Temperature: -25 ºC
– Maximum Operating Temperature: 70 ºC
– Conductor Structure: Rigid
– Bending Radius: Min 15xD
– Lead-free
Areas of Use
These center tube armored fiber optic cables are designed for duct or direct burial, outdoor environment cables.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Single or multi-core, single or multi-wire copper conductor, special flame-resistant separator layer, special synthetic insulation, galvanized round steel wire armor, special synthetic outer sheath, flame-retardant, halogen-free, non-smoking during fire and continue to function for 180 minutes under flame according to IEC 60331-21. (Armor is aluminum in single-core cables.)
Technical Information
– They are manufactured in accordance with TS IEC 60502-1.
– Permissible operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– Conductor Structure: Rigid
– LS (Low Smoke) Test: IEC 61034 -1/2
– Burning Droplet Test: IEC 60332-1-3
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-1-2 and IEC 60332-3-24 Cat.C
– FE (Current Conduction) Test: IEC 60331-21
Areas of Use
These cables are used in indoor and outdoor areas such as schools, hospitals, meetings and shopping malls where there are mandatory safety precautions against fire.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Multi-core, single or multi-wire copper conductor, special flame-resistant separator layer, special synthetic insulation, concentric copper conductor, special synthetic outer sheath, flame-retardant, halogen-free, non-smoking and 180 minutes flame-resistant energy and control cables according to IEC 60331-21.
Technical Information
– Manufactured in accordance with TS HD 604 S1 5G.
– Permissible operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– Conductor Structure: Rigid
– LS (Low Smoke) Test: IEC 61034 -1/2
– Burning Droplet Test: IEC 60332-1-3
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-1-2 and IEC 60332-3-24 Cat.C
– FE (Current Conduction) Test: IEC 60331-21
Areas of Use
These cables are used in indoor and outdoor areas such as schools, hospitals, meetings and shopping malls where there are mandatory safety precautions against fire.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Multi-core, single or multi-wire copper conductor, special flame-resistant separator layer, special synthetic insulation, concentric copper conductor, special synthetic outer sheath, flame-retardant, halogen-free, non-smoking and 180 minutes flame-resistant energy and control cables according to IEC 60331-21.
Technical Information
– Manufactured in accordance with TS HD 604 S1 5G.
– Permissible operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– Conductor Structure: Rigid
– LS (Low Smoke) Test: IEC 61034 -1/2
– Burning Droplet Test: IEC 60332-1-3
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-1-2 and IEC 60332-3-24 Cat.C
– FE (Current Conduction) Test: IEC 60331-21
Areas of Use
These cables are used in indoor and outdoor areas such as schools, hospitals, meetings and shopping malls where there are mandatory safety precautions against fire.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Single or multi-core, single or multi-wire copper conductor, special flame-resistant separator layer, special synthetic insulation, special synthetic outer sheath, flame-retardant, halogen-free, non-smoking and 180 minutes flame-resistant energy and control cables according to IEC 60331-21.
Technical Information
– Manufactured in accordance with TS HD 604 S1 5G.
– Permissible operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– Conductor Structure: Rigid
– LS (Low Smoke) Test: IEC 61034 -1/2
– Burning Droplet Test: IEC 60332-1-3
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-1-2 and IEC 60332-3-24 Cat.C
– FE (Current Conduction) Test: IEC 60331-21
Areas of Use
These cables are used in indoor and outdoor areas such as schools, hospitals, meetings and shopping malls where there are mandatory safety precautions against fire.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Single or multi-core, single or multi-wire copper conductor, special flame-resistant separator layer, special synthetic insulation, special synthetic outer sheath, flame-retardant, halogen-free, non-smoking and 180 minutes flame-resistant energy and control cables according to IEC 60331-21.
Technical Information
– Manufactured in accordance with TS HD 604 S1 5G.
– Permissible operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– Conductor Structure: Rigid
– LS (Low Smoke) Test: IEC 61034 -1/2
– Burning Droplet Test: IEC 60332-1-3
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-1-2 and IEC 60332-3-24 Cat.C
– FE (Current Conduction) Test: IEC 60331-21
Areas of Use
These cables are used in indoor and outdoor areas such as schools, hospitals, meetings and shopping malls where there are mandatory safety precautions against fire.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Single or multi-core, single or multi-wire copper conductor, special synthetic insulation, special synthetic outer sheath, flame retardant, halogen-free cables that do not create dense smoke during fire.
Technical Information
– Manufactured in accordance with TS HD 604 S1 5G.
– Permissible operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– Conductor Structure: Rigid
– LS (Low Smoke) Test: IEC 61034 -1/2
– Burning Droplet Test: IEC 60332-1-3
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-1-2 and IEC 60332-3-24 Cat.C
– CPR (Construction Materials Directive) Test: EN 50399
Areas of Use
These cables are used in indoor and outdoor areas such as schools, hospitals, meetings and shopping malls where there are mandatory safety precautions against fire.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Multi-core, fine multi-wire copper conductor, special synthetic insulation, special filling layer, special synthetic outer sheath, flame retardant, halogen-free energy cables.
Technical Information
– Manufactured in accordance with TSE 13751.
– Permissible operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– Conductor Structure: Flexible
– LS (Low Smoke) Test: IEC 61034 -1/2
– Burning Droplet Test: IEC 60332-1-3
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-1-2 and IEC 60332-3-24 Cat.C
– CPR (Construction Materials Directive) Test: EN 50399
Areas of Use
They are used in facilities with a fire risk such as hotels, hospitals, shopping malls, power plants and data processing centers, and in facilities where there are many people and valuable devices where mass transportation is carried out by rail systems. These cables do not transmit flame during a fire, do not create a dense smoke layer and do not create an environment suitable for corrosion, thus ensuring the safety of life and property.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Single-core, single-wire, multi-wire or fine multi-wire copper conductor, special synthetic insulation, flame retardant and halogen-free energy cables.
Technical Information
– Manufactured in accordance with TS EN 50525-3-31.
– Permissible operating temperature: 70 ºC
– Maximum Short Circuit Temperature: 160 ºC
– Conductor Structure: Flexible
– LS (Low Smoke) Test: IEC 61034 -1/2
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-1-2
– CPR (Construction Materials Directive) Test: EN 60332-1-2
Areas of Use
They are used as lighting and installation cables in dry spaces, switchgear facilities, distribution systems, and businesses.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file, or send it to the address you want via e-mail.