- Ana Sayfa
- Prysmian
- Telecom Solutions (Low Current Cables)
- Fiber Optic Cable Accessories
- FTTH Solutions
- WM049-06 Pre-Terminated CTB
WM049-06 Pre-Terminated CTB
Features and Benefits
• Eliminates the need for splicing in the customer premises.
• The Compact Termination box is pre-terminated in the factory to a length
of cable using SC/APC connectors.
• The standard cable lengths available are 30m or 50m. Other lengths can
be supplied. Contact Prysmian for further information.
• The standard cable type supplied is a 4mm diameter LSZH cable containing
an easy strip module, and up to four G657A2 fibres. Other cable types can
be supplied. Contact Prysmian for further information.
• Compact & attractive designed termination box for interior wall mounting.
• Supplied with a bracket that enables the box to be mounted to the wall
without removing the cover.
• The cable has a minimum bend radius of 10mm to allow cross wall routes
and door corner routes inside the premises. All fibres are positively
managed to maintain a 20mm minimum bend radius inside the CTB.
• Termination Box manufactured from fire resistant UL94-V0 rated material.
Cable sheath is LSZH (Low Smoke Zero Halogen).
• Patchcords exit the termination box on the bottom face and are protected
by the use of shuttered adapters.
• The standard termination box colour is white RAL9016. Other colours are
available on request.
• Fully tested in the factory. Each box is supplied with data for insertion loss
and return loss for each connector.
Technical Data – Termination Box
• Maximum Capacity: 4 Fibres
• Maximum no. of customer feeds: 4 Patchcords
• Required space envelope (mm): (l) 83 x (w) 100 x (d) 27
• Operating temperature: -20oC to + 50oC (5 to 95% RH)
• Material: FR ABS
• Colour: White RAL9016
• Testing:-
• Optical: Tested 1310,1550 & 1625nm
• Transportation: FT/RD/RESA/09/11/213 – 3.3
• Installation: FT/RD/RESA/09/11/213 – 3.4
• Climatic Storage: FT/RD/RESA/09/11/213 – 3.8
• Impact: FT/RD/RESA/09/11/213 – 3.8
• Cover Resistance: FT/RD/RESA/09/11/213 – 3.10
• Tensile: FT/RD/RESA/09/11/213 – 3.12
• Torsion: FT/RD/RESA/09/11/213 – 3.13
• Insertion Loss: FT/RD/RESA/09/11/213 – 3.14
• Climatic Testing: FT/RD/RESA/09/11/213 – 3.15
Ürün teknik özellik ve detayları için PDF ikonuna tıklayarak detayları görüntüleyebilir, dosyayı indirebilir veya istediğiniz adrese mail yolu ile ulaştırabilirsiniz.
Aynı Markalı Diğer Ürünlerimiz
Structure
The center tube contains the optical fibers and waterproof material, forming the cable core. Glass yarn material is applied around the cable core to increase dielectric strength. Black colored PE sheath is applied on the glass yarn material.
Technical Information
– Temperature in fixed conditions: -25 °C, +70 °C
– Temperature in moving conditions: -10 °C, +50 °C
– Minimum Operating Temperature: -25 ºC
– Maximum Operating Temperature: 70 ºC
– Conductor Structure: Rigid
– Bending Radius: Min 15xD
– Lead-free
Areas of Use
These center tube, unarmored fiber optic cables are designed for use in ducts.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
The center tube contains the optical fibers and waterproof material, forming the cable core. Glass yarn material is applied around the cable core to increase dielectric strength. Black colored PE sheath is applied on the glass yarn material.
Technical Information
– Temperature in fixed conditions: -25 °C, +70 °C
– Temperature in moving conditions: -10 °C, +50 °C
– Minimum Operating Temperature: -25 ºC
– Maximum Operating Temperature: 70 ºC
– Conductor Structure: Rigid
– Bending Radius: Min 15xD
– Lead-free
Areas of Use
These center tube, unarmored fiber optic cables are designed for use in ducts.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
The center tube contains the optical fibers and waterproof material, forming the cable core. Glass yarn material is applied around the cable core to increase dielectric strength. Black colored PE sheath is applied on the glass yarn material.
Technical Information
– Temperature in fixed conditions: -25 °C, +70 °C
– Temperature in moving conditions: -10 °C, +50 °C
– Minimum Operating Temperature: -25 ºC
– Maximum Operating Temperature: 70 ºC
– Conductor Structure: Rigid
– Bending Radius: Min 15xD
– Lead-free
Areas of Use
These center tube, unarmored fiber optic cables are designed for use in ducts.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
The center tube forms the cable core by containing optical fibers and waterproof material. To increase dielectric strength, glass yarn material is applied around the cable core. To protect the cable core from external factors, corrugated steel tape armor application is made, both sides of which are coated with copolymer material. Black colored PE sheath is applied on top of the armor.
Technical Information
– Temperature in fixed conditions: -25 °C, +70 °C
– Temperature in moving conditions: -10 °C, +50 °C
– Minimum Operating Temperature: -25 ºC
– Maximum Operating Temperature: 70 ºC
– Conductor Structure: Rigid
– Bending Radius: Min 15xD
– Lead-free
Areas of Use
These center tube armored fiber optic cables are designed for duct or direct burial, outdoor environment cables.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
The center tube forms the cable core by containing optical fibers and waterproof material. To increase dielectric strength, glass yarn material is applied around the cable core. To protect the cable core from external factors, corrugated steel tape armor application is made, both sides of which are coated with copolymer material. Black colored PE sheath is applied on top of the armor.
Technical Information
– Temperature in fixed conditions: -25 °C, +70 °C
– Temperature in moving conditions: -10 °C, +50 °C
– Minimum Operating Temperature: -25 ºC
– Maximum Operating Temperature: 70 ºC
– Conductor Structure: Rigid
– Bending Radius: Min 15xD
– Lead-free
Areas of Use
These center tube armored fiber optic cables are designed for duct or direct burial, outdoor environment cables.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Multi-core, single or multi-wire copper conductor, special flame-resistant separator layer, special synthetic insulation, concentric copper conductor, special synthetic outer sheath, flame-retardant, halogen-free, non-smoking and 180 minutes flame-resistant energy and control cables according to IEC 60331-21.
Technical Information
– Manufactured in accordance with TS HD 604 S1 5G.
– Permissible operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– Conductor Structure: Rigid
– LS (Low Smoke) Test: IEC 61034 -1/2
– Burning Droplet Test: IEC 60332-1-3
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-1-2 and IEC 60332-3-24 Cat.C
– FE (Current Conduction) Test: IEC 60331-21
Areas of Use
These cables are used in indoor and outdoor areas such as schools, hospitals, meetings and shopping malls where there are mandatory safety precautions against fire.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Single or multi-core, single or multi-wire copper conductor, special flame-resistant separator layer, special synthetic insulation, special synthetic outer sheath, flame-retardant, halogen-free, non-smoking and 180 minutes flame-resistant energy and control cables according to IEC 60331-21.
Technical Information
– Manufactured in accordance with TS HD 604 S1 5G.
– Permissible operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– Conductor Structure: Rigid
– LS (Low Smoke) Test: IEC 61034 -1/2
– Burning Droplet Test: IEC 60332-1-3
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-1-2 and IEC 60332-3-24 Cat.C
– FE (Current Conduction) Test: IEC 60331-21
Areas of Use
These cables are used in indoor and outdoor areas such as schools, hospitals, meetings and shopping malls where there are mandatory safety precautions against fire.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Multi-core, single or multi-wire copper conductor, special flame-resistant separator layer, special synthetic insulation, special synthetic outer sheath, flame-retardant, halogen-free, non-smoking and 180 minutes under flame function according to IEC 60331-21.
Technical Information
– Manufactured in accordance with TSE K 328.
– Permissible operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– Conductor Structure: Rigid
– LS (Low Smoke) Test: IEC 61034 -1/2
– Burning Droplet Test: IEC 60332-1-3
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-1-2 and IEC 60332-3-24 Cat.C
– FE (Current Conduction) Test: IEC 60331-21
Areas of Use
They are used in facilities with a fire risk such as hotels, hospitals, shopping malls, power plants and data processing centers, and in facilities where there are many people and valuable devices where mass transportation is carried out by rail systems. These cables do not transmit flame during a fire, do not create a dense smoke layer and do not create an environment suitable for corrosion, thus ensuring the safety of life and property.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Single-core, multi-wire, copper conductor, PROTOTHEN®–X (XLPE) insulation with very low dielectric losses, special inner and outer semiconductor layers that homogenize the electrical field, copper screen with a section suitable for high short-circuit currents and specially reinforced, water-swellable tape layer, aluminum protective sheath and polyethylene outer sheath high voltage energy cables. The screen is watertight in longitudinal and radial directions. If desired, longitudinal watertightness can be provided in the conductor.
Technical Information
– They are manufactured according to TS 10382 IEC 60840.
– Permissible Operating Temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC (Short circuit time t ≤ 5 sec.)
– Conductor Structure: Rigid
– Test Voltage (AC): 2.5Uo (30 min.)
Areas of Use
These cables are located underground, in concrete channels and / or PVC-PE pipes, in places where aerial high voltage lines cannot enter city centers due to safety, health and visual pollution, and they connect energy production / distribution places transformer centers to national / international distribution networks.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Three-core, multi-wire, copper conductor, PROTOTHEN®-X (XLPE) insulation with very low dielectric losses, special inner and outer semi-conductor layers that homogenize the electrical field, specially added copper screen with a suitable cross-section against high short circuit currents, flat galvanized steel wire armor and galvanized steel holding tape, LSOH outer sheathed medium voltage energy cables.
Technical Information
-They are manufactured according to TS IEC 60502-2.
– Permissible Operating Temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC (Short circuit time t ≤ 5 sec.)
– Conductor Structure: Rigid
– FR (Flame Resistance) Test: IEC 60332-1-2
– Test Voltage (AC): 3.5Uo
– Galvanized Flat Steel Wire Armored
Areas of Use
These cables, which have very low electrical losses compared to their counterparts, are used in electrical energy supply of large residential and industrial areas with large short circuit currents and in networks where load increases are expected, outdoors, in cable ducts, indoors and underground. When specially produced, they are used in fresh and salt water.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Medium voltage energy cables with single core, multi-wire, copper conductor, PROTOTHEN®-X (XLPE) insulation with very low dielectric losses, special inner and outer semiconductor layers that homogenize the electrical field, specially added copper screen against high short circuit currents with a suitable cross-section, LSOH outer sheath.
Technical Information
-They are manufactured according to TS IEC 60502-2.
– Permissible Operating Temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC (For short circuit time t ≤ 5 sec.)
– Conductor Structure: Rigid
– FR (Flame Resistance) Test: IEC 60332-1-2
– Test Voltage (AC): 3.5Uo
Areas of Use
These cables, which have much lower electrical losses than their counterparts, are used in electrical energy supply of residential and industrial areas with high short circuit currents and in networks where load increases are expected, outdoors, in cable ducts, indoors and underground. When specially produced, they are used in fresh and salt water.
Structure
Three-core, multi-wire, copper conductor, PROTOTHEN®-X (XLPE) insulation with very low dielectric losses, special inner and outer semi-conductor layers that homogenize the electrical field, specially added copper screen with a suitable cross-section against high short circuit currents, flat galvanized steel wire armor and galvanized steel holding tape, LSOH outer sheathed medium voltage energy cables.
Technical Information
-They are manufactured according to TS IEC 60502-2.
– Permissible Operating Temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC (Short circuit time t ≤ 5 sec.)
– Conductor Structure: Rigid
– FR (Flame Resistance) Test: IEC 60332-1-2
– Test Voltage (AC): 3.5Uo
– Galvanized Flat Steel Wire Armored
Areas of Use
These cables, which have very low electrical losses compared to their counterparts, are used in electrical energy supply of settlements and industrial zones where short circuit currents are high and in networks where load increases are expected, outdoors, in cable ducts, indoors and underground. When specially produced, they are used in fresh and salt water.
For product technical specifications and details, you can click on the PDF icon to view the details, download the file or send it to the address you want via e-mail.