OP017-10 Prysmian Tube Distribution Closure MKII
Features and Benefits
• Suitable for Blown Fibre and mini cable applications.
• Robust IP68 construction ensures suitability for direct bury applications.
• Quick release toggle clips reduce installation time and enable rapid reentry.
• Integral pressure relief valve prevents accidental over-pressurisation.
• For butt applications a plug is available to seal the unused end of the
in-line entry port.
• Can accommodate an in-line blown fibre tube cable/duct between
16.5mm and 40mm in diameter.
• Two further drop ports on each end can accommodate cables/ducts of
between 14.5mm and 24.5mm in diameter. Up to two small
cables/ducts between 10 and 11.5mm in diameter can also be
accommodated in each of these ports using a manifold. The manifold
can also be used to accommodate up to four cables into an end drop
port providing the cables are between 8 and 10mm in diameter.
• A further six drop ports (3 on each side) allow for cables/ducts between
8 and 11.5mm in diameter, or between 14.5 and 16.5mm in diameter.
• Drop cable glands are supplied separately. The closure has knock-out
ports for the glands, eliminating the need for plugs in unused ports. A
tool is available to knock-out the cable ports.
• The drop cable glands are designed to grip the cables/ducts in two
positions. This provides cable retention in both axial and lateral
directions. The glands also seal the cable/duct in two positions.
• The Tube Distribution Closure is supplied with an instruction flysheet. A
more detailed installation guide is available on request from Prysmian.
Technical Data
• Number of ports: 1×2 In-Line port, 4 End Ports, 6 Side Ports
• Blown Tube Cable Capacities:
(Based on cables containing 5mm tubes)
In-Line Port: 7, 12, 19 and 24 Blown Tube Cables
End Port: 4×1, 4, 7 and 12 Blown Tube Cables
Side Port: 1 and 4 Tube Cables
• Dimensions (mm): (l) 550 x (w) 290 x (d) 108
• Material:
Closure: GF Polypropylene (Black)
Toggles: GF Polypropylene (Orange)
Glands: Acetal (Black)
Seal: Rubber (Black)
• Testing:-
Dry heat: BS EN 60068-2-2 Test Bb
Damp heat: IEC 68-2-3
Temperature: IEC 68-2-14
Vibration: IEC 60068-2-6: 1995
Shock: IEC 60068-2-27: 1987
Ürün teknik özellik ve detayları için PDF ikonuna tıklayarak detayları görüntüleyebilir, dosyayı indirebilir veya istediğiniz adrese mail yolu ile ulaştırabilirsiniz.
Aynı Markalı Diğer Ürünlerimiz
Structure
The cable core is formed by bending thermoplastic tubes containing up to 12 single/multi mode optical fibers and waterproof material together with the fibers and a sufficient number of elements (tubes or fillers) together with the SZ method. The cable core is filled with filling material for longitudinal waterproofing. Glass yarn material is wrapped on the filled cable core for environmental reinforcement. Black colored PE sheath is applied on the glass yarn material.
Technical Information
– Temperature in fixed conditions: -30 °C, +70 °C
– Temperature in moving conditions: -10 °C, +50 °C
– Minimum Operating Temperature: -30 ºC
– Maximum Operating Temperature: 70 ºC
– Conductor Structure: Rigid
– Bending Radius: Min 10xD
– Lead-free
Areas of Use
These multi-tube, dielectric fiber optic cables are external environment cables designed for use in channels.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
The center tube contains the optical fibers and waterproof material, forming the cable core. Glass yarn material is applied around the cable core to increase dielectric strength. Black colored PE sheath is applied on the glass yarn material.
Technical Information
– Temperature in fixed conditions: -25 °C, +70 °C
– Temperature in moving conditions: -10 °C, +50 °C
– Minimum Operating Temperature: -25 ºC
– Maximum Operating Temperature: 70 ºC
– Conductor Structure: Rigid
– Bending Radius: Min 15xD
– Lead-free
Areas of Use
These center tube, unarmored fiber optic cables are designed for use in ducts.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
The center tube forms the cable core by containing optical fibers and waterproof material. To increase dielectric strength, glass yarn material is applied around the cable core. To protect the cable core from external factors, corrugated steel tape armor application is made, both sides of which are coated with copolymer material. Black colored PE sheath is applied on top of the armor.
Technical Information
– Temperature in fixed conditions: -25 °C, +70 °C
– Temperature in moving conditions: -10 °C, +50 °C
– Minimum Operating Temperature: -25 ºC
– Maximum Operating Temperature: 70 ºC
– Conductor Structure: Rigid
– Bending Radius: Min 15xD
– Lead-free
Areas of Use
These center tube armored fiber optic cables are designed for duct or direct burial, outdoor environment cables.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
The center tube forms the cable core by containing optical fibers and waterproof material. To increase dielectric strength, glass yarn material is applied around the cable core. To protect the cable core from external factors, corrugated steel tape armor application is made with copolymer material on both sides. Black colored PE sheath is applied on the armor.
Technical Information
– Temperature in fixed conditions: -25 °C, +70 °C
– Temperature in moving conditions: -10 °C, +50 °C
– Minimum Operating Temperature: -25 ºC
– Maximum Operating Temperature: 70 ºC
– Conductor Structure: Rigid
– Bending Radius: Min 15xD
– Lead-free
Areas of Use
These center tube armored fiber optic cables are designed for duct or direct burial, outdoor environment cables.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Single or multi-core, single or multi-wire copper conductor, special flame-resistant separator layer, special synthetic insulation, galvanized round steel wire armor, special synthetic outer sheath, flame-retardant, halogen-free, non-smoking during fire and continue to function for 180 minutes under flame according to IEC 60331-21. (Armor is aluminum in single-core cables.)
Technical Information
– They are manufactured in accordance with TS IEC 60502-1.
– Permissible operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– Conductor Structure: Rigid
– LS (Low Smoke) Test: IEC 61034 -1/2
– Burning Droplet Test: IEC 60332-1-3
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-1-2 and IEC 60332-3-24 Cat.C
– FE (Current Conduction) Test: IEC 60331-21
Areas of Use
These cables are used in indoor and outdoor areas such as schools, hospitals, meetings and shopping malls where there are mandatory safety precautions against fire.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Multi-core, single or multi-wire copper conductor, special flame-resistant separator layer, special synthetic insulation, concentric copper conductor, special synthetic outer sheath, flame-retardant, halogen-free, non-smoking and 180 minutes flame-resistant energy and control cables according to IEC 60331-21.
Technical Information
– Manufactured in accordance with TS HD 604 S1 5G.
– Permissible operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– Conductor Structure: Rigid
– LS (Low Smoke) Test: IEC 61034 -1/2
– Burning Droplet Test: IEC 60332-1-3
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-1-2 and IEC 60332-3-24 Cat.C
– FE (Current Conduction) Test: IEC 60331-21
Areas of Use
These cables are used in indoor and outdoor areas such as schools, hospitals, meetings and shopping malls where there are mandatory safety precautions against fire.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Multi-core, single or multi-wire copper conductor, special flame-resistant separator layer, special synthetic insulation, concentric copper conductor, special synthetic outer sheath, flame-retardant, halogen-free, non-smoking and 180 minutes flame-resistant energy and control cables according to IEC 60331-21.
Technical Information
– Manufactured in accordance with TS HD 604 S1 5G.
– Permissible operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– Conductor Structure: Rigid
– LS (Low Smoke) Test: IEC 61034 -1/2
– Burning Droplet Test: IEC 60332-1-3
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-1-2 and IEC 60332-3-24 Cat.C
– FE (Current Conduction) Test: IEC 60331-21
Areas of Use
These cables are used in indoor and outdoor areas such as schools, hospitals, meetings and shopping malls where there are mandatory safety precautions against fire.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Multi-core, multi-wire, copper conductor, special synthetic insulated, galvanized flat steel wire armored, special synthetic outer sheathed, flame retardant, halogen-free and non-smoking energy cables.
Technical Information
– Manufactured in accordance with TS IEC 60502-1.
– Permissible operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– Conductor Structure: Rigid
– LS (Low Smoke) Test: IEC 61034 -1/2
– Burning Droplet Test: IEC 60332-1-3
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-1-2 and IEC 60332-3-24 Cat.C
– Galvanized Flat Steel Wire Armored
Areas of Use
These cables are resistant to mechanical external effects thanks to the armor consisting of galvanized flat steel wires on them. They are used in places where mandatory safety precautions are taken against fire.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Single or multi-core, single or multi-wire, copper conductor, three or four-core, special synthetic insulated, galvanized round steel wire armored, special synthetic outer sheathed, flame retardant, halogen-free and non-smoking energy cables. (Aluminum in single-core cables.)
Technical Information
– Manufactured in accordance with TS IEC 60502-1.
– Permissible operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– Conductor Structure: Rigid
– LS (Low Smoke) Test: IEC 61034 -1/2
– Burning Droplet Test: IEC 60332-1-3
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-1-2 and IEC 60332-3-24 Cat.C
– CPR (Construction Materials Directive) Test: EN 60332-1-2
– Galvanized Round Steel Wire Armored
Areas of Use
These cables are resistant to mechanical external effects thanks to the armor consisting of galvanized round steel wires on them. They are used in places where there are mandatory safety precautions against fire.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Single or multi-core, single or multi-wire copper conductor, special synthetic insulation, special synthetic outer sheath, flame retardant, halogen-free cables that do not create dense smoke during fire.
Technical Information
– Manufactured in accordance with TS HD 604 S1 5G.
– Permissible operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– Conductor Structure: Rigid
– LS (Low Smoke) Test: IEC 61034 -1/2
– Burning Droplet Test: IEC 60332-1-3
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-1-2 and IEC 60332-3-24 Cat.C
– CPR (Construction Materials Directive) Test: EN 50399
Areas of Use
These cables are used in indoor and outdoor areas such as schools, hospitals, meetings and shopping malls where there are mandatory safety precautions against fire.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Multi-core, fine multi-wire copper conductor, special synthetic insulation, special filling layer, special synthetic outer sheath, flame retardant, halogen-free energy cables.
Technical Information
– Manufactured in accordance with TSE 13751.
– Permissible operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– Conductor Structure: Flexible
– LS (Low Smoke) Test: IEC 61034 -1/2
– Burning Droplet Test: IEC 60332-1-3
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-1-2 and IEC 60332-3-24 Cat.C
– CPR (Construction Materials Directive) Test: EN 50399
Areas of Use
They are used in facilities with a fire risk such as hotels, hospitals, shopping malls, power plants and data processing centers, and in facilities where there are many people and valuable devices where mass transportation is carried out by rail systems. These cables do not transmit flame during a fire, do not create a dense smoke layer and do not create an environment suitable for corrosion, thus ensuring the safety of life and property.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Single-core, single-wire, multi-wire or fine multi-wire copper conductor, special synthetic insulation, flame retardant and halogen-free energy cables.
Technical Information
– Manufactured in accordance with TS EN 50525-3-31.
– Permissible operating temperature: 70 ºC
– Maximum Short Circuit Temperature: 160 ºC
– Conductor Structure: Flexible
– LS (Low Smoke) Test: IEC 61034 -1/2
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-1-2
– CPR (Construction Materials Directive) Test: EN 60332-1-2
Areas of Use
They are used as lighting and installation cables in dry spaces, switchgear facilities, distribution systems, and businesses.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file, or send it to the address you want via e-mail.