- Ana Sayfa
- Prysmian
- Telecom Solutions (Low Current Cables)
- Fiber Optic Cable Accessories
- Additional Boxes
- OP014-06 Modular Jointing OPGW
OP014-06 Modular Jointing OPGW
Features and Benefits
• The joint can be used for straight, branch spur or tee applications.
• Stainless Steel Base and Cap available in two sizes.
• The closure base has either 4 circular entry ports (2 x OPGW cable and up to
2 x Branch Cables) or 6 circular entry ports (2 x OPGW and up to 4 branch
cables).
• Insulated cable inlet for OPGW cables.
• For each type of trays, splice holders are available for crimp, heat shrinkable
or mechanical (for SEM only) splice protectors.
• All fibres are positively managed to maintain a 30mm minimum bend radius.
• Splice trays hinge upwards individually, allowing full access to spliced fibres
without disturbance to live fibres in adjacent trays.
• Splitter modules can be mounted within the joint and can be supplied preassembled. Any combination of splitters between 1×2 to 1×16 can be
accommodated. Please contact Prysmian for splitter part numbers.
• Cables up to 22 mm in diameter can be installed into each port.
• The joint is quickly re-enterable and the sealing clamp can be locked.
Technical Data
• Number of cable ports: 4 circular (2 x OPGW cable + 2 branch cables) Short Cap
6 circular (2 x OPGW cable + 4 branch cables) Long Cap
• Maximum cable diameter (mm): Ø22 (Ø14.6mm OPGW Cable, Ø22 for Dielectric Cables)
• Required space envelope (mm): (l) 560 x (d) 250 Short Cap
(l) 600 x (d) 250 Long Cap
Ürün teknik özellik ve detayları için PDF ikonuna tıklayarak detayları görüntüleyebilir, dosyayı indirebilir veya istediğiniz adrese mail yolu ile ulaştırabilirsiniz.
Aynı Markalı Diğer Ürünlerimiz
Structure
The cable core is formed by bending thermoplastic tubes containing up to 12 single/multi mode optical fibers and waterproof material together with the fibers and a sufficient number of elements (tubes or fillers) together with the SZ method. The cable core is filled with filling material for longitudinal waterproofing. Glass yarn material is wrapped on the filled cable core for environmental reinforcement. Black colored PE sheath is applied on the glass yarn material.
Technical Information
– Temperature in fixed conditions: -30 °C, +70 °C
– Temperature in moving conditions: -10 °C, +50 °C
– Minimum Operating Temperature: -30 ºC
– Maximum Operating Temperature: 70 ºC
– Conductor Structure: Rigid
– Bending Radius: Min 10xD
– Lead-free
Areas of Use
These multi-tube, dielectric fiber optic cables are external environment cables designed for use in channels.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
The center tube contains the optical fibers and waterproof material, forming the cable core. Glass yarn material is applied around the cable core to increase dielectric strength. Black colored PE sheath is applied on the glass yarn material.
Technical Information
– Temperature in fixed conditions: -25 °C, +70 °C
– Temperature in moving conditions: -10 °C, +50 °C
– Minimum Operating Temperature: -25 ºC
– Maximum Operating Temperature: 70 ºC
– Conductor Structure: Rigid
– Bending Radius: Min 15xD
– Lead-free
Areas of Use
These center tube, unarmored fiber optic cables are designed for use in ducts.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
The cable core is formed by bending thermoplastic tubes and sufficient number of elements (tubes or fillers) containing up to 12 single/multi mode optical fibers and waterproof material together with the fibers with the SZ method. The cable core is filled with filling material for longitudinal waterproofing. Glass yarn material is wrapped on the filled cable core for environmental reinforcement. Corrugated steel tape armor application is made, coated with copolymer material on both sides to protect the cable core from external factors. Black colored PE sheath is applied on the armor.
Technical Information
– Temperature in fixed conditions: -30 °C, +70 °C
– Temperature in moving conditions: -10 °C, +50 °C
– Minimum Operating Temperature: -30 ºC
– Maximum Operating Temperature: 70 ºC
– Conductor Structure: Rigid
– Bending Radius: Min 15xD
– Lead-free
Areas of Use
These multi-tube, armored fiber optic cables are designed for direct burial or in ducts, and are external environment cables.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
The center tube forms the cable core by containing optical fibers and waterproof material. To increase dielectric strength, glass yarn material is applied around the cable core. To protect the cable core from external factors, corrugated steel tape armor application is made, both sides of which are coated with copolymer material. Black colored PE sheath is applied on top of the armor.
Technical Information
– Temperature in fixed conditions: -25 °C, +70 °C
– Temperature in moving conditions: -10 °C, +50 °C
– Minimum Operating Temperature: -25 ºC
– Maximum Operating Temperature: 70 ºC
– Conductor Structure: Rigid
– Bending Radius: Min 15xD
– Lead-free
Areas of Use
These center tube armored fiber optic cables are designed for duct or direct burial, outdoor environment cables.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
The center tube forms the cable core by containing optical fibers and waterproof material. To increase dielectric strength, glass yarn material is applied around the cable core. To protect the cable core from external factors, corrugated steel tape armor application is made, both sides of which are coated with copolymer material. Black colored PE sheath is applied on top of the armor.
Technical Information
– Temperature in fixed conditions: -25 °C, +70 °C
– Temperature in moving conditions: -10 °C, +50 °C
– Minimum Operating Temperature: -25 ºC
– Maximum Operating Temperature: 70 ºC
– Conductor Structure: Rigid
– Bending Radius: Min 15xD
– Lead-free
Areas of Use
These center tube armored fiber optic cables are designed for duct or direct burial, outdoor environment cables.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Single or multi-core, single or multi-wire copper conductor, special flame-resistant separator layer, special synthetic insulation, galvanized round steel wire armor, special synthetic outer sheath, flame-retardant, halogen-free, non-smoking during fire and continue to function for 180 minutes under flame according to IEC 60331-21. (Armor is aluminum in single-core cables.)
Technical Information
– They are manufactured in accordance with TS IEC 60502-1.
– Permissible operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– Conductor Structure: Rigid
– LS (Low Smoke) Test: IEC 61034 -1/2
– Burning Droplet Test: IEC 60332-1-3
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-1-2 and IEC 60332-3-24 Cat.C
– FE (Current Conduction) Test: IEC 60331-21
Areas of Use
These cables are used in indoor and outdoor areas such as schools, hospitals, meetings and shopping malls where there are mandatory safety precautions against fire.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Single or multi-core, single or multi-wire copper conductor, special flame-resistant separator layer, special synthetic insulation, galvanized round steel wire armor, special synthetic outer sheath, flame-retardant, halogen-free, non-smoking during fire and continue to function for 180 minutes under flame according to IEC 60331-21. (Armor is aluminum in single-core cables.)
Technical Information
– They are manufactured in accordance with TS IEC 60502-1.
– Permissible operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– Conductor Structure: Rigid
– LS (Low Smoke) Test: IEC 61034 -1/2
– Burning Droplet Test: IEC 60332-1-3
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-1-2 and IEC 60332-3-24 Cat.C
– FE (Current Conduction) Test: IEC 60331-21
Areas of Use
These cables are used in indoor and outdoor areas such as schools, hospitals, meetings and shopping malls where there are mandatory safety precautions against fire.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Single or multi-core, single or multi-wire copper conductor, special flame-resistant separator layer, special synthetic insulation, special synthetic outer sheath, flame-retardant, halogen-free, non-smoking and 180 minutes flame-resistant energy and control cables according to IEC 60331-21.
Technical Information
– Manufactured in accordance with TS HD 604 S1 5G.
– Permissible operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– Conductor Structure: Rigid
– LS (Low Smoke) Test: IEC 61034 -1/2
– Burning Droplet Test: IEC 60332-1-3
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-1-2 and IEC 60332-3-24 Cat.C
– FE (Current Conduction) Test: IEC 60331-21
Areas of Use
These cables are used in indoor and outdoor areas such as schools, hospitals, meetings and shopping malls where there are mandatory safety precautions against fire.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Medium voltage energy cables with single core, multi-wire, copper conductor, very low dielectric loss PROTOTHEN®-X (XLPE) insulation, special inner and outer semi-conductor layers that homogenize the electrical field, specially added copper screen against high short circuit currents, LSOH outer sheath.
Technical Information
– They are manufactured in accordance with TSE K 204 and based on IEC 60502-2.
– Permissible Operating Temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC (Short circuit time t ≤ 5 sec.)
– Conductor Structure: Rigid
– FR (Flame Resistance) Test: IEC 60332-1-2
– Test Voltage (AC): 3.5Uo
Areas of Use
These cables, which have very low electrical losses compared to their counterparts, are used in electrical energy supply of residential and industrial areas where short circuit currents are high and in networks where load increases are expected, outdoors, in cable ducts, indoors and underground. When specially produced, they are used in fresh and salt water.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Medium voltage energy cables with single core, multi-wire, copper conductor, very low dielectric loss PROTOTHEN®-X (XLPE) insulation, special inner and outer semi-conductor layers that homogenize the electrical field, specially added copper screen against high short circuit currents, LSOH outer sheath.
Technical Information
– They are manufactured in accordance with TSE K 204 and based on IEC 60502-2.
– Permissible Operating Temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC (Short circuit time t ≤ 5 sec.)
– Conductor Structure: Rigid
– FR (Flame Resistance) Test: IEC 60332-1-2
– Test Voltage (AC): 3.5Uo
Areas of Use
These cables, which have very low electrical losses compared to their counterparts, are used in electrical energy supply of residential and industrial areas where short circuit currents are high and in networks where load increases are expected, outdoors, in cable ducts, indoors and underground. When specially produced, they are used in fresh and salt water.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Three-core, multi-wire, copper conductor, very low dielectric losses
PROTOTHEN®-X (XLPE) insulation, special inner and outer semi-conductor layers that homogenize the electrical field, suitable cross-section against high short-circuit currents
and specially added copper screen, flat galvanized steel wire armor and galvanized steel holding tape, halogen-free, does not create a dense smoke layer during fire and LSOH outer sheathed medium voltage energy cables
Technical Information
These cables are manufactured in accordance with TS IEC 60502-2.
– Permissible operating temperature: 90 ºC
– Permissible short circuit temperature: 250 ºC
(For short circuit time t ≤ 5 sec.)
They are tested in accordance with the following standards:
LS (Low Smoke) Test: IEC 61034-1/2
Burning Droplet Test: IEC 60332-1-3
HF (Halogen Free) Test: IEC 60754-1/2
FR (Flame Resistance) Test: IEC 60332-1-2 and IEC 60332-3-24 Cat.C
Places of Use
These cables, which have very low electrical losses compared to their counterparts, are used in electrical energy supply of residential and industrial areas where short circuit currents are high and in networks where load increases are expected, outdoors, in cable ducts and indoors.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Three-core, multi-wire, copper conductor, PROTOTHEN®-X (XLPE) insulation with very low dielectric losses, special inner and outer semi-conductor layers that homogenize the electrical field, specially added copper screen with a suitable cross-section against high short circuit currents, flat galvanized steel wire armor and galvanized steel holding tape, LSOH outer sheathed medium voltage energy cables.
Technical Information
-They are manufactured according to TS IEC 60502-2.
– Permissible Operating Temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC (Short circuit time t ≤ 5 sec.)
– Conductor Structure: Rigid
– FR (Flame Resistance) Test: IEC 60332-1-2
– Test Voltage (AC): 3.5Uo
– Galvanized Flat Steel Wire Armored
Areas of Use
These cables, which have very low electrical losses compared to their counterparts, are used in electrical energy supply of settlements and industrial zones where short circuit currents are high and in networks where load increases are expected, outdoors, in cable ducts, indoors and underground. When specially produced, they are used in fresh and salt water.
For product technical specifications and details, you can click on the PDF icon to view the details, download the file or send it to the address you want via e-mail.