Delta Tema Elektrik
Scroll to top

Arama sonuçları: fiber optik kablolar

RM022-04 SRS3000 Connectorised Splitter Shelf

RM022-04 SRS3000 Connectorised Splitter Shelf

Features and Benefits • High density cost effective design for housing connectorised splitters in racks or cabinets. • Compatible with all connecter types. • Dedicated input and output positions for the splitter legs. • Unit manufactured from high strength fire retardant plastic to give a light weight solution. • Supplied with connectorised splitters pre-installed by Prysmian. The number of splitters per shelf depends on the configuration and connector type. The part number tables on pages 2 to 4 show all of the configurations possible. • All fibres are positively managed to a 30mm minimum bend radius. • Shelf pivots out to enable access to the splitter storage area for maintenance. • Ideal for high density FTTH applications with Passive Optical Networks (PON). • Can be mounted in racks, wall cabinets and street-side cabinets. • Compatible with the SRS3000 product range. • Patch cord are bend managed for extra protection. • Note: for shelves totalling more than 24 patch cords (input + output) 2mm patch cords must be usedTechnical Data • Max number of outputs: 32 • Required space envelope (mm): (w) 480 x (d) 245 x (h) 44.5 • Operating temperature: -20oC to + 60oC (5 to 93% RH) • Material:- • Metalwork: Mild Steel • Plastics: High Impact Polystyrene • Finish:- • Metalwork: Painted Light Grey RAL 7035 • Plastics: Light Grey RAL 7035 • Testing:- • Optical: Tested 1310nm,1550nm and 1625nm • Vibration: IEC 60068-2-6: 1995 • Shock: IEC 60068-2-27: 1987Ürün teknik özellik ve detayları için PDF ikonuna tıklayarak detayları görüntüleyebilir, dosyayı indirebilir veya istediğiniz adrese mail yolu ile ulaştırabilirsiniz.

Administrator 24 Eylül 2019
RM014-06 SRS3000 1U Splice And Patch Shelf

RM014-06 SRS3000 1U Splice And Patch Shelf

Features and Benefits •Modular panel design enables easy capacity upgrades from 12 to 48 fibres. • Very high splice and patch density of 48 fibres for SC and LC connector types in 1U. • High splice and patch density of 24 fibres for ST, FC and E2000 connector types in 1U. • Suitable for installation into 19”/ ETSI / ANSI racks, wall mounted cabinets and street-side cabinets. • Splice and patch module pivots outwards for easy fibre access and maintenance. •The drop down front panel prevents accidental disconnection of patchcords and provides additional space for patchcord routing during installations. • All fibres are positively bend managed to a 30mm radius • Supplied with a large cover label and front panel labels for easy identification and data recording. • Splice and patch bay is covered with a detachable lid (secured with two screws) to protect the splices and pigtails once installed. •The panel can be used for optical splitters and other passive devices in alternative configurations. Please contact Prysmian for further information. • Can accommodate most cable types including blown fibre tube cables. Note: for 48f 1U shelves a 2mm Patch-cord size should be used.Technical Data • Max number of terminations 48 for SC or LC connectors 24 for FC, ST and E2000 connectors • Max number of patchcords out: 48 with 2mm diameter patch cords • Max Cable Diameter: 14mm • Required space envelope (mm): (w) 480 x (d) 245 x (h) 44.5 • Operating temperature: -20oC to + 60oC (5 to 93% RH) • Material:- • Metalwork: Mild Steel • Plastics: High Impact Polystyrene • Finish:- • Metalwork: Painted light grey RAL 7035 • Plastics: Light Grey RAL 7035 • Testing:- • Optical: Tested at 1310nm,1550nm and 1625nm • Dry heat: BS EN 60068-2-2 Test Bb • Damp heat: IEC 60068-2-3: 1969 • Change of temperature: IEC 60068-2-14: 1984 • Vibration: IEC 60068-2-6: 1995 • Shock: IEC 60068-2-27: 1987Ürün teknik özellik ve detayları için PDF ikonuna tıklayarak detayları görüntüleyebilir, dosyayı indirebilir veya istediğiniz adrese mail yolu ile ulaştırabilirsiniz.

Administrator 24 Eylül 2019
RM019-04 SRS3000 1U Patch Only Shelf

RM019-04 SRS3000 1U Patch Only Shelf

Features and Benefits •Modular panel design enables easy capacity upgrades from 12 to 48 adapters. • Very high patch density of 48 adapters for SC and LC connector types in 1U and High patch density of 24 adapters for ST, FC and E2000 connector types in 1U. • Suitable for installation into 19”/ ETSI / ANSI racks, wall mounted cabinets and streetside cabinets. • Patch module pivots outwards for easy fibre access and maintenance. • The panel can be used for optical splitters and other passive devices in alternative configurations. Please contact Prysmian for further information. • The drop down front panel prevents accidental disconnection of patchcords and provides additional space for patchcord routing during installations. • All fibres are positively bend managed to a 30mm radius • Supplied with a large cover label and front panel labels for easy identification and data recording. • Patch bay is covered with a detachable lid (secured with two screws) to protect the fibres once installed. • Can accommodate most cable types including blown fibre tube cables. Note: for 48f 1U shelves a 2mm Patch-cord size should be used.Technical Data • Max number of terminations 48 for SC or LC connectors 24 for FC, ST and E2000 connectors • Max number of output patchcords: 48 with 2mm diameter patch cords • Max Cable Diameter: 14mm • Required space envelope (mm): (w) 480 x (d) 245 x (h) 44.5 • Operating temperature: -20oC to + 60oC (5 to 93% RH) • Material:- • Metalwork: Mild Steel • Plastics: High Impact Polystyrene • Finish:- • Metalwork: Painted light grey RAL 7035 • Plastics: Light Grey RAL 7035 • Testing:- • Optical: Tested at 1310nm,1550nm and 1625nm • Dry heat: BS EN 60068-2-2 Test Bb • Damp heat: IEC 60068-2-3: 1969 • Change of temperature: IEC 60068-2-14: 1984 • Vibration: IEC 60068-2-6: 1995 • Shock: IEC 60068-2-27: 1987Ürün teknik özellik ve detayları için PDF ikonuna tıklayarak detayları görüntüleyebilir, dosyayı indirebilir veya istediğiniz adrese mail yolu ile ulaştırabilirsiniz.

Administrator 24 Eylül 2019
RM018-04 SRS3000 1U Splice Only Shelf

RM018-04 SRS3000 1U Splice Only Shelf

Features and Benefits • Suitable for installation into 19”/ ETSI / ANSI racks, wall mounted cabinets and street-side cabinets. • The shelf has a capacity of up to 48 fibre splices. • The shelf is supplied with splice protector holders for 2.2mm heat shrink splice protectors. Crimp splice protectors can also be accommodated by using crimp splice protector holders. Refer to additional items. • Can accommodate most cable types including blown fibre tube cables. • Splice module pivots outwards for easy fibre access and maintenance. • The shelf can be used for optical splitters and other passive devices in alternative configurations. Please contact Prysmian for further information. • The drop down front panel prevents accidental disconnection of fibre routing tubes during installations. • All fibres are positively bend managed to a 30mm radius • Supplied with a large cover label and front panel labels for easy identification and data recording. • Splice bay is covered with a detachable lid (secured with two screws) to protect the fibres once installed.Technical Data • Max number of splices 48 • Splice protectors accommodated: 2.2mm heat shrink or crimp • Max number of output patchcords: 48 with 2mm diameter patch cords • Max Cable Diameter: 14mm • Required space envelope (mm): (w) 480 x (d) 245 x (h) 44.5 • Operating temperature: -20oC to + 60oC (5 to 93% RH) • Material:- • Metalwork: Mild Steel • Plastics: High Impact Polystyrene • Finish:- • Metalwork: Painted light grey RAL 7035 • Plastics: Light Grey RAL 7035 • Testing:- • Optical: Tested at 1310nm,1550nm and 1625nm • Dry heat: BS EN 60068-2-2 Test Bb • Damp heat: IEC 60068-2-3: 1969 • Change of temperature: IEC 60068-2-14: 1984 • Vibration: IEC 60068-2-6: 1995 • Shock: IEC 60068-2-27: 1987Ürün teknik özellik ve detayları için PDF ikonuna tıklayarak detayları görüntüleyebilir, dosyayı indirebilir veya istediğiniz adrese mail yolu ile ulaştırabilirsiniz.

Administrator 24 Eylül 2019
RM015-07 SRS3000 Distribution Sub Rack

RM015-07 SRS3000 Distribution Sub Rack

Features and Benefits ƒ Modular system for installation into 19” / ETSI / ANSI racks, street-side cabinets and wall mounted cabinets. ƒ The sub-rack can be supplied fully configured or modules can be supplied empty for upgrading at a later date. ƒ Chassis are available in 1U, 2U and 3U options are supplied front mounted as standard. Rear mounting brackets are available as an option. ƒ Fibres are actively managed to minimum bend diameters throughout the Splicing and Patching, Patching only, Splicing only, Patchcord Storage and Splitter Modules. ƒ Splicing and bare fibre excess storage is performed inside a tray protected by a cover to prevent any accidental damage when open & closing the shelves. ƒ Modules pivot outwards for easy access. ƒ Cables are completely protected from entry to exit of the panel. ƒ Optical devices (i.e. Splitters & WDM’s) can be mounted within the modules. Please contact Prysmian to discuss your requirements) ƒ Wall mount 19” and ETSI cabinets are also available. Please contact Prysmian for further details. ƒ Modules have drop down fronts for easier patchcord routing, enclosing patch-cords, and protecting adapters. ƒ 2 large labelling areas provided for identification recording per module.Technical Data • Max number of splices • 1U 48 ( SC & LC), 24 ( FC, ST & E2000) • 2U 96 (SC & LC), 48 (FC, ST & E2000) • 3U 144 (SC & LC), 72 (FC, ST & E2000) • Max number of output patchcords: • 1U 48 with 2mm diameter patch cords • 2U 96 with 2mm diameter patch cords • 3U 144 with 2mm diameter patch cords • Max Cable Diameter (mm): 14 • Required space envelope (mm): • 1U: (w) 480 x (d) 245 x (h) 44.5 • 2U (w) 480 x (d) 245 x (h) 89.0 • 3U (w) 480 x (d) 245 x (h) 133.5 • Operating temperature: -20oC to + 60oC (5 to 93% RH) • Material:- • Metalwork: Mild Steel • Plastics: High Impact Polystyrene • Finish:- • Metalwork: Painted light grey RAL 7035 • Plastics: Light Grey RAL 7035 • Testing:- • Optical: Tested at 1310nm,1550nm and 1625nm • Dry heat: BS EN 60068-2-2 Test Bb • Damp heat: IEC 60068-2-3: 1969 • Change of temperature: IEC 60068-2-14: 1984 • Vibration: IEC 60068-2-6: 1995 • Shock: IEC 60068-2-27: 1987Ürün teknik özellik ve detayları için PDF ikonuna tıklayarak detayları görüntüleyebilir, dosyayı indirebilir veya istediğiniz adrese mail yolu ile ulaştırabilirsiniz.

Administrator 24 Eylül 2019
RM031-01 POS 1U - Tube Storage Pivoting Shelf

RM031-01 POS 1U - Tube Storage Pivoting Shelf

Features and Benefits • The POS is a robust metallic shelf that can be mounted in racks for indoor applications or street cabinets for outdoor applications. • Fits into standard 19” rails. Can be used in ETSI racks or cabinets using conversion brackets. Contact Prysmian for further details. • The shelf is equipped with a metallic cover. • The shelf is equipped with 3 metallic trays. • In each tray two stowage pockets enable the storage of up to 3 metres of 5mm OD tubes/cables per pocket. • The pivoting support can fix up to nine 5mm OD tubes/cables and an 11.5mm OD cable. • The shelf is 1U in height.Technical Data • Number of cable ports: 9 • Maximum cable diameter (mm): 5 • Required space envelope (mm): 19" x 275mm (d) (240+35mm) H=1U (44.4mm) • Operating temperature: -25oC to + 70oC (5 to 95% RH) • Material: Mild Steel, Painted light grey RAL 7035 • Testing: • Fibre bending radius (mm): minimum 15mm (ITU-T G.657 A2 fibre) • Cable retention: IEC 61300-2-4 [4] • Thermal choc IEC 61300-2-22 [12] • Corrosion test IEC 60068-2-11 [5] • Vibration test IEC 61300-2-1 Ed3 [2] . • Cable retention IEC 61300-2-4 [4] . • Torsion test IEC 61300-2-5 Ed3 [5] • Flexion test IEC 61300-2-37 Ed2 [13] • Shock IEC 61300-2-9 Ed 2.0 [7] • Crush test IEC 61300-2-10 • Fall test IEC 61300-2-12 [8] • Temp. cycling EN 61300-2-22[12]Ürün teknik özellik ve detayları için PDF ikonuna tıklayarak detayları görüntüleyebilir, dosyayı indirebilir veya istediğiniz adrese mail yolu ile ulaştırabilirsiniz.

Administrator 24 Eylül 2019
RM013-07 Connectorised Splitter Shelf

RM013-07 Connectorised Splitter Shelf

Features and Benefits • High density cost effective compact design for housing connectorised splitters in racks or cabinets. • Compatible with SC and LC connecter types. • Dedicated input and output positions for the splitter legs. • Unit manufactured from high strength fire retardant plastic to give a light weight solution. • Supplied with connectorised splitters pre-installed by Prysmian. • All fibres are positively managed to a 30mm minimum bend radius. • Shelf pivots out to enable access to the splitter storage area for maintenance. • Ideal for high density FTTH applications with Passive Optical Networks (PON) • Can be mounted in racks, wall cabinets and street-side cabinetsTechnical Data • Required space envelope (mm): (w) 481 x (d) 230 x (h) 44 • Operating temperature: -20oC to + 50oC (5 to 95% RH) • Material: High Impact Polystyrene • Colour Grey RAL 7035 • Testing:- • Optical: Tested 1310nm,1550nm and 1625nm • Vibration: IEC 60068-2-6: 1995 • Shock: IEC 60068-2-27: 1987Ürün teknik özellik ve detayları için PDF ikonuna tıklayarak detayları görüntüleyebilir, dosyayı indirebilir veya istediğiniz adrese mail yolu ile ulaştırabilirsiniz.

Administrator 24 Eylül 2019
RM012-15 PSP Splice And Patch Shelf

RM012-15 PSP Splice And Patch Shelf

Features and Benefits • High density low cost compact design for up to 48 fibres. • Compatible with SC, FC, E2000, LC, ST connecter types. • Cables anchor on the rear of the unit using a cable anchor plate supplied. • Unit manufactured from high strength fire retardant plastic to give a light weight solution. • Supplied either as an empty unit, in kit format (with pigtails and adapters in a bag) for installer loading, or with the pigtails and adapters pre-installed by Prysmian. • All fibres are positively managed to a 30mm minimum bend radius. • Shelf pivots out to for access to the splice tray and pigtail area. • Shelf can be used as a patch only solution and allows excess cable lengths to be stored. • Stackable splice bay allows for easy upgrade of splicing capacity. • The shelf offers the ability to terminate up to 2 cables and allows through splicing of fibres. • Compatible with Sirocco blown fibre cables using a Blown Fibre Manifold. The manifold enables up to 6 blown fibre tubes to be routed to a single shelf. • Available in 2 colours – grey RAL 7035 and black.Technical Data • No of splice trays: 1 • Maximum fibre capacity 24 (ST, FC, E2000) 48 (SC, LC) • Max. Cable Diameter (mm): 18 • Cable capacity: 2 • Required space envelope (mm): (w) 481 x (d) 230 x (h) 44 • Operating temperature: -20o C to + 50o C (5 to 95% RH) • Material: High Impact Polystyrene (Fire Retardant) • Colour: Light Grey RAL 7035 or Black • Testing: • Optical: Tested at 1310nm and 1550nm • Dry heat: BS EN 60068-2-2 Test Bb • Damp heat: IEC 68-2-3 • Change of temperature IEC 68-2-14 • Vibration: IEC 68-2-6 • Shock: IEC 68-2-27Ürün teknik özellik ve detayları için PDF ikonuna tıklayarak detayları görüntüleyebilir, dosyayı indirebilir veya istediğiniz adrese mail yolu ile ulaştırabilirsiniz.

Administrator 24 Eylül 2019
RM011-08 Sliding Sub-Rack Splicing & Patching

RM011-08 Sliding Sub-Rack Splicing & Patching

Features and Benefits • Provides management of fibres through Splicing and Patching. • Splicing and bare fibre excess storage is performed inside a splice tray protected by a cover. • Compatible with 19” and ETSI racks. • Supplied with 72 Adapters and pigtails pre-installed onto the splice trays ready for connection to cable fibres. • The shelf can accommodate a variety of different connector types. • Shelf pulls outwards to enable easy access to the splice trays. • Modules hinge upwards to provide access to the module below. • compatible with the OAsys Modular Main Rack. • Fully bend managed to 30mm minimum bend radius.Technical Data • Max number of Adapters: 72 • Max number of Splices: 72 • Required space envelope (mm): 19” - (w) 415 x (d) 280 x (h) 133.5 ETSI – (w) 495 x (d) 280 x (h) 133.5 • Operating temperature: -20oC to + 50oC (5 to 95% RH) • Material:- • Metalwork: Mild Steel • Plastics: FR Polymer • Finish:- • Metalwork: Painted light grey (RAL 7035) • Plastics: Grey • Testing:- • Optical: Tested at 1310nm and 1550nm • Dry heat: BS EN 60068-2-2 Test Bb • Damp heat: IEC 60068-2-3: 1969 • Change of temperature: IEC 60068-2-14: 1984 • Vibration: IEC 60068-2-6: 1995 • Shock: IEC 60068-2-27: 1987Ürün teknik özellik ve detayları için PDF ikonuna tıklayarak detayları görüntüleyebilir, dosyayı indirebilir veya istediğiniz adrese mail yolu ile ulaştırabilirsiniz.

Administrator 24 Eylül 2019
RM010-07 Sliding Sub-Rack Patching

RM010-07 Sliding Sub-Rack Patching

Features and Benefits • For use in both 19” and ETSI standard racks. • Provides management of fibres through patching. • Shelf pulls outwards to enable easy access to the patching modules. • Modules hinge upwards to provide access to the module below. • The shelf can accommodate a variety of different connector types. • Supplied with 72 adapters pre-installed to save installation time. • Compatible with the OAsys Modular Main Rack. • Fully bend managed to 30mm minimum bend radius.Technical Data • Max Number of Adapters: 72 • Required space envelope (mm): 19” - (w) 415 x (d) 280 x (h) 133.5 ETSI – (w) 495 x (d) 280 x (h) 133.5 • Operating temperature: -20oC to + 50oC (5 to 95% RH) • Material:- • Metalwork: Mild Steel • Plastics: FR Polymer • Finish:- • Metalwork: Painted light grey (RAL 7035) • Plastics: Grey • Testing:- • Optical: Tested at 1310nm and 1550nm • Dry heat: BS EN 60068-2-2 Test Bb • Damp heat: IEC 60068-2-3: 1969 • Change of temperature: IEC 60068-2-14: 1984 • Vibration: IEC 60068-2-6: 1995 • Shock: IEC 60068-2-27: 1987Ürün teknik özellik ve detayları için PDF ikonuna tıklayarak detayları görüntüleyebilir, dosyayı indirebilir veya istediğiniz adrese mail yolu ile ulaştırabilirsiniz.

Administrator 24 Eylül 2019
RM030-01 MOE96 1,5U – 96 S Pivoting Shelf

RM030-01 MOE96 1,5U – 96 S Pivoting Shelf

Features and Benefits • The MOE96 is a robust metallic shelf that can be mounted in racks for indoor applications or street cabinets for outdoor applications. • Fits into standard 19” rails. Can be used in ETSI racks or cabinets using conversion brackets. Contact Prysmian for further details. • The shelf is equipped with a metallic cover. • The shelf is equipped with two rows of twelve 4fo splice trays for a total of 96 splices. • The pivoting support can fix up to six 5mm OD tubes/cables and a 11.5mm OD cable. • The shelf is 1.5U in height.Technical Data • Number of cable ports: 6 + 1 • Maximum cable diameter (mm): 5 or 11,5 • Maximum number of splice trays: 24 • Maximum fibre capacity : 96 (4fo x 24) • Required space envelope (mm): 19" x 275mm (d) (240+35mm) H=1.5U (66.6mm) • Operating temperature: -25oC to + 70oC (5 to 95% RH) • Material: Mild Steel, Painted light grey RAL 7035 • testing: • Optical: Tested 1310nm,1550nm and 1625nm • Fibre bending radius (mm): Minimum 15mm (ITU-T G.657 A2 fibre) • Cable retention: IEC 61300-2-4 [4] • Thermal choc IEC 61300-2-22 [12] • Corrosion test IEC 60068-2-11 [5] • Vibration test IEC 61300-2-1 Ed3 [2] . • Cable retention IEC 61300-2-4 [4] . • Torsion test IEC 61300-2-5 Ed3 [5] • Flexion test IEC 61300-2-37 Ed2 [13] • Shock IEC 61300-2-9 Ed 2.0 [7] • Crush test IEC 61300-2-10 • Fall test IEC 61300-2-12 [8] • Temp. cycling EN 61300-2-22[12]Ürün teknik özellik ve detayları için PDF ikonuna tıklayarak detayları görüntüleyebilir, dosyayı indirebilir veya istediğiniz adrese mail yolu ile ulaştırabilirsiniz.

Administrator 24 Eylül 2019
AC030-01 Pre-Connectorised Optical Riser Cable - 25%

AC030-01 Pre-Connectorised Optical Riser Cable - 25%

Features and Benefits • Available in fibre counts of 48, 96 or 144. • All of the yellow fibres supplied terminated with SC/APC connectors. • Test certificate supplied with each assembly. • Supplied with G.657.A2 BendBright®-XS fibres. • Gel free micro modules for faster installation.Ürün teknik özellik ve detayları için PDF ikonuna tıklayarak detayları görüntüleyebilir, dosyayı indirebilir veya istediğiniz adrese mail yolu ile ulaştırabilirsiniz.

Administrator 24 Eylül 2019
RM032-01 MEC32 1U – 32FO Preterminated Splitter Pivoting Shelf

RM032-01 MEC32 1U – 32FO Preterminated Splitter Pivoting Shelf

Features and Benefits • The MEC32 is a robust metallic shelf that can be mounted in racks for indoor applications or street cabinets for outdoor applications. • Fits into standard 19” rails. Can be used in ETSI racks or cabinets using conversion brackets. Contact Prysmian for further details. • The shelf is equipped with a metallic cover. • The shelf is equipped with a 32fo front patch panel with 8 columns of 4 single SC/APC adapter positions. • The shelf is equipped with one 12fo splice tray to splice the input fibres from the pre-terminated splitters. If the splitter input fibres are also preterminated, a patch panel is available inside the shelf for up to 8 SC positions. • A drop down front panel protects and guides the patchcords. • The pivoting support can fix up to two 5mm OD tubes/cables. • The shelf is 1U in height.Technical Data • Number of cable ports: 2 • Maximum cable diameter (mm): 5 • Maximum number of splice trays: 1 • Patch capacity 32 + 8 SC • Maximum fibre capacity : 12 (12fo x 1) • Required space envelope (mm): 19" x 275mm (d) (240+35mm) H=1U • Operating temperature: -25oC to + 70oC (5 to 95% RH) • Material: Mild Steel, Painted light grey RAL 7035 • Testing: • Optical: Tested 1310nm,1550nm and 1625nm • Fibre bending radius (mm): Minimum 15mm (ITU-T G.657 A2 fibre) • Cable retention: IEC 61300-2-4 [4] • Thermal choc IEC 61300-2-22 [12] • Corrosion test IEC 60068-2-11 [5] • Vibration test IEC 61300-2-1 Ed3 [2] . • Cable retention IEC 61300-2-4 [4] . • Torsion test IEC 61300-2-5 Ed3 [5] • Flexion test IEC 61300-2-37 Ed2 [13] • Shock IEC 61300-2-9 Ed 2.0 [7] • Crush test IEC 61300-2-10 • Fall test IEC 61300-2-12 [8] • Temp. cycling EN 61300-2-22[12]

Administrator 24 Eylül 2019
AC017-03 Verticasa Storage Reel

AC017-03 Verticasa Storage Reel

Features and Benefits • Used to temporarily store an extracted fibre module. • Inner diameter of 180mm ensures fibre bend radius is not compromised. • The fibre module can be wound on the reel as its extracted from the riser cable. • Light weight plastic construction.Technical Data • Reel inner diameter: 180mm • Reel flange diameter: 230mm • Reel Height: 65mm • Material: Polypropylene • Finish:- TransparentÜrün teknik özellik ve detayları için PDF ikonuna tıklayarak detayları görüntüleyebilir, dosyayı indirebilir veya istediğiniz adrese mail yolu ile ulaştırabilirsiniz.

Administrator 24 Eylül 2019
2U Drawer Splice & Patch Shelf

2U Drawer Splice & Patch Shelf

Features and Benefits • Modular panel design enables easy capacity upgrades from 12 to 96 fibres. • Excellent optical fibre cord management, minimum cable and patchcords movement. • Patchcords exit the unit from the front of the shelf. • Pull out drawer for easy access for splicing and maintenance. • Can accommodate up to 48 adapters of ST, FC, SC, E2000 and duplex LC type. • Can accommodate up to 4 splice trays each able to accommodate up to 24 splices. • Suitable for installation into 19”/ ETSI racks, wall mounted cabinets and street-side cabinets. • Manufactured from steel painted light grey Ral 7035 • Supplied either as an empty unit, in kit format (with pigtails and adapters in a bag) for installer loading. • All fibres are positively managed to a 30mm minimum bend radius. • Shelf has a pull out drawer for access to the splice tray and pigtail area. • Cables enter the unit from the rear. Up to 4 cables can of up to 21mm in diameter can be accommodated. •The panel can be used for optical splitters and other passive devices in alternative configurations. Please contact Prysmian for further information.Technical Data : • Max number of terminations: 48 with FC, ST, E2000 or SC, 96 with LC • Connector types: FC, ST, E2000, SC or LC • Max number of cable in: 4 • Max cable diameter: 21mm • Max number of patchcords out: 48 with FC, ST, E2000 or SC, 96 with LC • Max number of splice trays: 2 • Splice tray capacity: 24 splices each • Required space envelope (mm): (w) 482 x (d) 300 x (h) 89 • Operating temperature: -10oC to + 50oC (5 to 90% RH) • Material: Steel • Finish: Painted light grey RAL 7035Ürün teknik özellik ve detayları için PDF ikonuna tıklayarak detayları görüntüleyebilir, dosyayı indirebilir veya istediğiniz adrese mail yolu ile ulaştırabilirsiniz.

Administrator 24 Eylül 2019