Ürünler
Areas of Use
0.6/1 kV halogen-free, flame-retardant single or multi-core energy cables should be used in fire-sensitive areas and spaces such as high-rise buildings, shopping malls, hospitals, schools, where people are very densely located.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file, or send it to the address you want via e-mail.
Structure
Single or multi-core, single or multi-wire copper conductor, special synthetic insulation, special synthetic outer sheath, flame retardant, halogen-free cables that do not create dense smoke during fire.
Technical Information
– Manufactured in accordance with TS HD 604 S1 5G.
– Permissible operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– Conductor Structure: Rigid
– LS (Low Smoke) Test: IEC 61034 -1/2
– Burning Droplet Test: IEC 60332-1-3
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-1-2 and IEC 60332-3-24 Cat.C
– CPR (Construction Materials Directive) Test: EN 50399
Areas of Use
These cables are used in indoor and outdoor areas such as schools, hospitals, meetings and shopping malls where there are mandatory safety precautions against fire.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Single or multi-core, single or multi-wire copper conductor, special flame-resistant separator layer, special synthetic insulation, special synthetic outer sheath, flame-retardant, halogen-free, non-smoking and 180 minutes flame-resistant energy and control cables according to IEC 60331-21.
Technical Information
– Manufactured in accordance with TS HD 604 S1 5G.
– Permissible operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– Conductor Structure: Rigid
– LS (Low Smoke) Test: IEC 61034 -1/2
– Burning Droplet Test: IEC 60332-1-3
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-1-2 and IEC 60332-3-24 Cat.C
– FE (Current Conduction) Test: IEC 60331-21
Areas of Use
These cables are used in indoor and outdoor areas such as schools, hospitals, meetings and shopping malls where there are mandatory safety precautions against fire.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Single or multi-core, single or multi-wire copper conductor, special flame-resistant separator layer, special synthetic insulation, special synthetic outer sheath, flame-retardant, halogen-free, non-smoking and 180 minutes flame-resistant energy and control cables according to IEC 60331-21.
Technical Information
– Manufactured in accordance with TS HD 604 S1 5G.
– Permissible operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– Conductor Structure: Rigid
– LS (Low Smoke) Test: IEC 61034 -1/2
– Burning Droplet Test: IEC 60332-1-3
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-1-2 and IEC 60332-3-24 Cat.C
– FE (Current Conduction) Test: IEC 60331-21
Areas of Use
These cables are used in indoor and outdoor areas such as schools, hospitals, meetings and shopping malls where there are mandatory safety precautions against fire.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Areas of Use
0.6/1 kV XLPE insulated, galvanized steel wire armored single or multi-core cables are suitable for heavy operating conditions where protection against external effects and mechanical strength are important. They are resistant to sudden and short-term operating temperature increases. They are used in fire-sensitive places and spaces such as high-rise buildings, shopping malls, hospitals, schools where people are very densely located.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Areas of Use
0.6/1 kV XLPE insulated, galvanized steel wire armored single or multi-core cables are suitable for heavy operating conditions where protection against external effects and mechanical strength are important. They are resistant to sudden and short-term operating temperature increases.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Areas of Use
0.6/1 kV Cu / XLPE / PVC single or multi-core cables are used in places where higher operating temperatures are required (90°C), indoors and outdoors where there is no excessive mechanical stress, underground and in cable ducts. Resistant to sudden and short-term operating temperature increases.
For product technical specifications and details, you can click on the PDF icon to view the details, download the file or send it to the address you want via e-mail.
Areas of Use
0.6/1 kV Cu / XLPE / PVC single or multi-core cables; are used in places where higher operating temperatures are required (90°C), indoors and outdoors where there is no excessive mechanical stress, underground and in cable ducts. Resistant to sudden and short-term operating temperature increases.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Areas of Use
As power and control cables;
In devices and machines that need to work during a fire (emergency elevators, fire water systems, etc.)
In ventilation systems connected to the fire alarm system
In lighting fire escape routes
In emergency power supplies
In places where human life, valuable materials and equipment need to be protected
In places where there is electromagnetic interference and interference
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Areas of Use
As power and control cables;
In devices and machines that need to work during a fire (emergency elevators, fire water systems, etc.)
In ventilation systems connected to the fire alarm system
In lighting fire escape routes
In emergency power sources
In places where human life, valuable materials and equipment need to be protected
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Areas of Use
These cables, which continue their function in case of fire, are used as power and control cables in emergency and lighting systems;
Airports, hospitals, shopping malls
Tunnels, metro stations
High-rise buildings, hotels
Industrial facilities
Where human life, valuable materials and equipment need to be protected.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Single-core, single-wire, multi-wire or fine multi-wire copper conductor, special synthetic insulation, flame retardant and halogen-free energy cables.
Technical Information
– Manufactured in accordance with TS EN 50525-3-31.
– Permissible operating temperature: 70 ºC
– Maximum Short Circuit Temperature: 160 ºC
– Conductor Structure: Flexible
– LS (Low Smoke) Test: IEC 61034 -1/2
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-1-2
– CPR (Construction Materials Directive) Test: EN 60332-1-2
Areas of Use
They are used as lighting and installation cables in dry spaces, switchgear facilities, distribution systems, and businesses.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file, or send it to the address you want via e-mail.
Structure
Multi-core, single or multi-wire copper conductor, special flame-resistant separator layer, special synthetic insulation, special synthetic outer sheath, flame-retardant, halogen-free, non-smoking and 180 minutes under flame function according to IEC 60331-21.
Technical Information
– Manufactured in accordance with TSE K 328.
– Permissible operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– Conductor Structure: Rigid
– LS (Low Smoke) Test: IEC 61034 -1/2
– Burning Droplet Test: IEC 60332-1-3
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-1-2 and IEC 60332-3-24 Cat.C
– FE (Current Conduction) Test: IEC 60331-21
Areas of Use
They are used in facilities with a fire risk such as hotels, hospitals, shopping malls, power plants and data processing centers, and in facilities where there are many people and valuable devices where mass transportation is carried out by rail systems. These cables do not transmit flame during a fire, do not create a dense smoke layer and do not create an environment suitable for corrosion, thus ensuring the safety of life and property.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Multi-core, solid or stranded, copper conductor, PROTODUR® (PVC) insulated, PROTODUR® (PVC) outer sheathed antigron cables.
Technical Information
– Manufactured according to TS HD 21.4 S2.
– Permissible Operating Temperature: 70 ºC
– Maximum Short Circuit Temperature: 160 ºC
– Conductor Structure: Rigid
– FR (Flame Resistance) Test: IEC 60332-1-2
– CPR (Construction Materials Directive) Test: EN 60332-1-2
– Test Voltage (AC): 2 kV
Areas of Use
They are used in dry, humid and wet places, in workshops, factories and all kinds of workplaces and warehouses with fire and explosion risks, outdoors, they are not laid underground, they are used fixedly in pipes, on plaster and under plaster.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Areas of Use
0.6/1 kV galvanized steel tape armored cables are suitable for heavy operating conditions where protection against external effects and mechanical strength are important.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Areas of Use
0.6/1 kV concentric copper tape conductor cables are generally used underground. The concentric conductor allows the monitoring of external impacts coming to the cable by connecting to the protection switch and/or relay.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.