Ürünler
Structure
Single or multi-core, single or multi-wire, copper conductor, PROTOTHEN®-X (XLPE) insulated, PROTODUR® (PVC) outer sheathed energy cables.
Technical Information
-Manufactured according to TS IEC 60502-1.
– Permissible Operating Temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC (Short circuit time t ≤ 5 sec.)
– Conductor Structure: Rigid
– FR (Flame Resistance) Test: IEC 60332-1-2
– CPR (Construction Materials Directive) Test: EN 60332-1-2
– Test Voltage (AC): 3.5 kV
Areas of Use
They are used as energy, network and lighting cables outdoors, in cable ducts, underground, and in fresh and salt water when specially produced.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Single or multi-core, single or multi-wire, copper conductor, PROTOTHEN®-X (XLPE) insulated, PROTODUR® (PVC) outer sheathed energy cables.
Technical Information
-Manufactured according to TS IEC 60502-1.
– Permissible Operating Temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC (Short circuit time t ≤ 5 sec.)
– Conductor Structure: Rigid
– FR (Flame Resistance) Test: IEC 60332-1-2
– CPR (Construction Materials Directive) Test: EN 60332-1-2
– Test Voltage (AC): 3.5 kV
Areas of Use
They are used as energy, network and lighting cables outdoors, in cable ducts, underground, and in fresh and salt water when specially produced.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Single or multi-core, single or multi-wire, copper conductor PROTOTHEN®-X (XLPE) insulated, galvanized round steel wire armored, PROTODUR® (PVC) outer sheathed energy cables. (Aluminum in single-core cables.)
Technical Information
-They are manufactured according to TS IEC 60502-1.
– Permissible Operating Temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC (Short circuit time t ≤ 5 sec.)
– Conductor Structure: Rigid
– FR (Flame Resistance) Test: IEC 60332-1-2
– CPR (Construction Materials Directive) Test: EN 60332-1-2
– Test Voltage (AC): 3.5 kV
– Galvanized Round Steel Wire Armored
Areas of Use
These cables are very resistant to mechanical external effects thanks to the armor made of galvanized round steel wires on them. They are suitable for heavy operating, laying and assembly conditions. They are used underground and in fresh and salt water when specially produced.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Single or multi-core, single or multi-wire, copper conductor PROTOTHEN®-X (XLPE) insulated, galvanized round steel wire armored, PROTODUR® (PVC) outer sheathed energy cables. (Aluminum in single-core cables.)
Technical Information
-They are manufactured according to TS IEC 60502-1.
– Permissible Operating Temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC (Short circuit time t ≤ 5 sec.)
– Conductor Structure: Rigid
– FR (Flame Resistance) Test: IEC 60332-1-2
– CPR (Construction Materials Directive) Test: EN 60332-1-2
– Test Voltage (AC): 3.5 kV
– Galvanized Round Steel Wire Armored
Areas of Use
These cables are very resistant to mechanical external effects thanks to the armor made of galvanized round steel wires on them. They are suitable for heavy operating, laying and assembly conditions. They are used underground and in fresh and salt water when specially produced.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Multi-core, multi-wire, copper conductor, PROTOTHEN®-X (XLPE) insulated, galvanized flat steel wire armor, cross-holding steel tape, PROTODUR® (PVC) outer sheathed energy cables.
Technical Information
-Manufactured according to TS IEC 60502-1.
– Permissible Operating Temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC (Short circuit time t ≤ 5 sec.)
– Conductor Structure: Rigid
– FR (Flame Resistance) Test: IEC 60332-1-2
– CPR (Construction Materials Directive) Test: EN 60332-1-2
– Test Voltage (AC): 3.5 kV
– Galvanized Flat Steel Wire Armored
Areas of Use
These cables are very resistant to mechanical external effects thanks to the armor made of flat steel wires on them. They are suitable for heavy operating, laying and assembly conditions. They are used underground and in fresh and salt water when specially produced.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.