You are here:

Showing 1217–1232 of 3173 results

Ürünler

Areas of Use
They are manufactured in accordance with the TSE K 116 standard. They are used as switchboard and subscriber distribution cables in fixed installations inside the building. These cables are made of HFFR material, are slow to ignite and largely self-extinguishing. They have low smoke density and do not emit toxic and corrosive gases. They are used in buildings where there are many people and important materials.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Construction
Inner conductor: solid copper wire, bare, diameter 0.6 mm
Insulation: Foam-PE, diameter 2.8 mm
Outer conductor: Al-PET-Al-foil under tinned copper braid, diameter 3.4 mm
Sheath: FRNC, diameter 4.5 mm Anthracite
Printing: DRAKA – HD PRO 0.6/2.8 AF – 75 Ω ± 1% + batch number + metermarking

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Construction
Inner conductor: solid copper wire, bare, diameter 0.6 mm
Insulation: Foam-PE, diameter 2.8 mm
Outer conductor: Al-PET-Al-foil under tinned copper braid, diameter 3.4 mm
Sheath: FRNC, diameter 4.5 mm Anthracite
Printing: DRAKA – HD PRO 0.6/2.8 AF – 75 Ω ± 1% + batch number + metermarking

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Construction
Inner conductor: solid copper wire, bare, diameter 1.0 mm
Insulation: Foam-PE, diameter 4.8 mm
Outer conductor: Al-PET-Al-foil under tinned copper braid, diameter 5.6 mm
Sheath: FRNC diameter 7.0 mm anthracite
Printing: DRAKA – HD PRO 1.0/4.8 AF – 75 Ω ± 1%

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Construction
Inner conductor: stranded copper wire, diameter 1.0 mm
Insulation: Foam-PE, diameter 4.8 mm
Outer conductor: 2xCu-braid, tinned
Sheath: DMC FLEX PVC diameter 7.0 mm black, RAL 9005
Printing: DRAKA COMTEQ – HD PRO FLEX 1.0L/4.8Dz – 75 Ω ± 1% – HDTV

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Areas of Use
These types of cables using HFFR material are used for control, imaging and measurement purposes in office machines, electronic control systems, heating and ventilation systems, power plants, and engineering projects. They have a very flexible structure due to the use of fine multi-wire copper as the inner conductor. They can be used in indoor environments, dry or humid places. They ignite late and largely self-extinguish due to the HFFR material. They have low smoke density and do not emit toxic and corrosive gases. They are used in places where people are densely populated and important materials are present.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Areas of Use
These cables, which are made of HFFR material and have double-layer shielding with Al-PES Tape and braid, are used in signal transmission in industrial applications. They can be easily applied in narrow spaces with their flexible structures in the communication sector, electronic circuits, measuring instruments, machine designs, office machines, computer systems and electronic control systems such as sound systems. They are used inside buildings. Shielding provides protection against external electrical effects. They ignite late due to HFFR material and are largely self-extinguishing. They have low smoke density and do not emit toxic and corrosive gases. They are used in buildings where people are densely populated and important materials are present.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Better Cable Protection
For Universal Applications

You can view the product technical specifications and details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
On the conductor made of copper wire, the cores coated with LSOH insulation in a thickness that will meet the electrical properties are twisted in pairs. These pairs are brought together and twisted in a coaxial fold to form the cable core. After the polyester tape (optional) with holding and protective properties is wrapped on this core, a longitudinal tin-plated earth wire and 1 layer of aluminum-coated polyester tape screen with the metal part facing inward are wrapped on top to ensure the continuity of the screen. The red LSOH sheath is coated on the screen. The outer sheath thickness will be in accordance with TSE K 173.

Technical Information
Temperature in fixed conditions: -30 °C, +70 °C
Temperature in moving conditions: -5 °C, +50 °C

Areas of Use
Used as a signal communication cable protected against electrical interference in fixed installations inside buildings.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Areas of Use
Halogen-free material J-H(st)H…Bd cables are used in telephone, measurement and control systems. These shielded cables are not affected by external electrical interference and provide continuity in signal quality. They are tested according to the IEC 60332-3 standard. They do not emit toxic corrosive gases and dense black smoke during combustion. They have special importance in terms of the protection and safety of human life and valuables in public buildings, schools, hotels, airports, hospitals, shopping malls, factories, etc.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Areas of Use
They are signal and data transmission cables used in fixed installations inside buildings. They are mainly preferred in fire alarm, security and internal telephone systems. These shielded cables provide continuity in signal quality by being protected from external electrical interference. HFFR material is used in J-H(St)H…Lg cables, they are late-igniting and largely self-extinguishing. They have low smoke density and do not emit toxic and corrosive gases. They are used in buildings where people are dense and important materials are present.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Placeholder

Areas of Use
In-building installations;
Telephone switchboards and subscriber distributions
Signal and data transmission

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
On the conductor made of copper wire, the cores coated with PVC insulation in accordance with TSE K 173, in a thickness that will meet the electrical properties, are twisted in pairs. These pairs are brought together and twisted in a coaxial fold to form the cable core. After a holding and protective polyester tape (optional) is wrapped on this core, a longitudinally tin-plated earth wire and 1 layer of aluminum-coated polyester tape screen with the metal part facing inward are wrapped on top to ensure the continuity of the screen.

A red colored sheath is coated on the screen. The outer sheath thickness shall be in accordance with TSE K 173.

Technical Information
Temperature in fixed conditions: -30 °C, +70 °C
Temperature in moving conditions: -5 °C, +50 °C

Areas of Use
Used as a signal communication cable protected against electrical interference in fixed installations inside buildings.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Placeholder

Areas of Use
In instrumentation and control engineering
In industrial electronics
In computer and office machines
In indoor communication systems
In indoor sound systems
In security systems

Notes
These types of cables are not suitable for use as power supply cables and in underground installations

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Placeholder

Areas of Use
In-building installations;
Telephone switchboards and subscriber distributions
Signal and data transmission

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Areas of Use
They are signal and data transmission cables used in fixed installations inside buildings. They are mainly preferred in fire alarm, security and internal telephone systems. These shielded cables are protected from external electrical interference and provide continuity in signal quality.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.