Ürünler
Areas of Use
In-building installations;
Telephone switchboards and subscriber distributions
Signal and data transmission
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
On a conductor made of copper wire, the cores coated with LSOH insulation, with a thickness that will meet the electrical properties, are twisted together in a star quad
shape to form the cable core. After a holding and protective polyester tape (optional) is wrapped on this core, a tin-plated earth wire and 1 layer of aluminum-coated polyester tape screen with the metal part turned inward are wrapped on it to ensure the continuity of the screen. A red LSOH sheath is coated on the screen. The outer sheath thickness shall be in accordance with TSE K 173.
Technical Information
Temperature in fixed conditions: -30 °C, +70 °C
Temperature in mobile conditions: -5 °C, +50 °C
Areas of Use
Used as a signal communication cable protected against electrical interference in fixed installations inside buildings.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
A flame barrier mica tape is helically wrapped on the conductor made of copper wire. The cable core is formed by twisting the cores coated with LSOH insulation on the mica tape conductors, which are thick enough to meet the electrical specifications, together in a star quad shape. After wrapping the polyester tape (optional) with holding and protective features on this core, a longitudinally tin-plated drain wire and 1 layer of aluminum-coated polyester tape screen with the metal part facing inward are wrapped on it to ensure the continuity of the screen. Orange-colored LSOH sheath is coated on the screen. The outer sheath thickness shall be in accordance with TSE K 173.
Technical Information
Temperature in fixed conditions: -30 °C, +70 °C
Temperature in moving conditions: -5 °C, +50 °C
Areas of Use
Used as a signal communication cable protected against electrical interference in fixed installations inside buildings.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Areas of Use
In closed environments where people are densely populated
In instrument and control engineering
In industrial electronics
In computer and office machines
In indoor communication systems
In security and fire alarm systems
In places where human life, valuable materials and equipment need to be protected
Notes
These types of cables are not suitable for use as power supply cables and in underground installations
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Areas of Use
They are used as signal transmission cables in industrial applications, control and measurement systems. They are suitable for internal fixed installations. These shielded cables are not affected by external electrical interferences and provide continuity in signal quality. HFFR material is used in these cables, which are tested according to the IEC 60332-3 standard, they are late-igniting and largely self-extinguishing. They have low smoke density and do not emit toxic and corrosive gases. They are used in areas where people are densely populated and important materials are present.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Areas of Use
Where there is electromagnetic interference and interference
In instrument and control engineering
In industrial electronics
In computer and office machines
In indoor communication systems
In indoor sound systems
In security systems
Notes
They can be easily applied in narrow spaces with their flexible structures.
These types of cables are not used in outdoor environments.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Areas of Use
They are used as signal transmission cables in industrial applications, control and measurement systems. They are suitable for internal fixed installations. These shielded cables are not affected by external electrical interferences and provide continuity in signal quality. HFFR material is used in these cables tested according to IEC 60332-3 standard, they are late-igniting and largely self-extinguishing. They have low smoke density and do not emit toxic and corrosive gases. They are used in areas where people are dense and important materials are present.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
0.4-0.5-0.6 and 0.9 mm diameter, annealed electrolytic copper conductor, foamed polyethylene insulation, quadruple twisted, unfilled, polyethylene inner sheathed with aluminum tape, polyethylene outer sheathed suspension rope aerial line telephone cables.
Technical Information
Temperature in fixed conditions: -30 °C, +70 °C
Temperature in mobile conditions: -5 °C, +50 °C
Areas of Use
They are used in communication and distribution networks of telephone exchanges, subscriber distribution networks, and also in signal and control circuits. They can be drawn into concrete channels, PVC or cement pipes or directly buried in the ground.
Structure
0.4-0.5-0.6 and 0.9 mm diameter, annealed electrolytic copper conductor, foamed polyethylene insulation, quadruple twisted, unfilled, aluminum tape on LSOH inner sheath, LSOH outer sheathed telephone cables.
Technical Information
Temperature in fixed conditions: -30 °C, +70 °C
Temperature in mobile conditions: -5 °C, +50 °C
Areas of Use
They are used in communication and distribution networks of telephone exchanges, subscriber distribution networks, and also in signal and control circuits. They can be drawn into concrete channels, LSOH or cement pipes or buried directly in the ground.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
0.4-0.5-0.6 and 0.9 mm diameter, annealed electrolytic copper conductor, foamed polyethylene insulation, quadruple twisted, unfilled, aluminum tape on polyethylene inner sheath, polyethylene outer sheathed telephone cables.
Technical Information
Temperature in fixed conditions: -30 °C, +70 °C
Temperature in mobile conditions: -5 °C, +50 °C
Areas of Use
They are used in telephone switchboards’ communication and distribution networks, subscriber distribution networks, and also in signal and control circuits. They can be drawn into concrete channels, PVC or cement pipes or buried directly in the ground.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Areas of Use
In-building installations;
Telephone switchboards and subscriber distributions
Signal and data transmission
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
0.4-0.5-0.6 and 0.9 mm diameter, annealed electrolytic copper conductor, foamed polyethylene insulation, quadruple twisted, filled, aluminum tape screened, polyethylene outer sheathed telephone cables.
Technical Information
Temperature in fixed conditions: -30 °C, +70 °C
Temperature in mobile conditions: -5 °C, +50 °C
Areas of Use
They are used in telephone switchboards’ communication and distribution networks, subscriber distribution networks, and also in signal and control circuits. They can be drawn into concrete channels, PVC or cement pipes or buried directly in the ground.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
0.4-0.5-0.6 and 0.9 mm diameter, annealed electrolytic copper conductor, foamed polyethylene insulation, quadruple twisted, filled, aluminum tape screened, polyethylene outer sheathed suspension rope aerial line telephone cables.
Technical Information
Temperature in fixed conditions: -30 °C, +70 °C
Temperature in mobile conditions: -5 °C, +50 °C
Areas of Use
They are used in telephone switchboards’ communication and distribution networks, subscriber distribution networks, and also in signal and control circuits. They can be drawn into concrete channels, PVC or cement pipes or directly buried in the ground.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Areas of Use
In closed environments where there is electromagnetic interference and interference
People are densely populated
In instrument and control engineering
In industrial electronics
In computer and office machines
In indoor communication systems
In indoor sound systems
In places where human life and important materials need to be protected
Notes
They can be easily applied in narrow spaces with their flexible structures.
These types of cables are not used in outdoor environments.
LI-2Y(ST)CH-OZ: Number-coded black cores.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Areas of Use
They are used in data communication in computer connections and electronic control systems in industrial automation systems. Compared to RS 232-422, they provide more comprehensive data transmission over longer transmission distances. HFFR versions are less flammable in the event of a fire and are mostly self-extinguishing. These cables, which have low smoke density, do not emit toxic and corrosive gases during a fire.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Areas of Use
They are used in data communication in computer connections and electronic control systems in industrial automation systems. Compared to RS 232-422, they provide more comprehensive data transmission over longer transmission distances. HFFR versions are less flammable in case of fire and are mostly self-extinguishing. These cables, which have low smoke density, do not emit toxic and corrosive gases during a fire.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.