You are here:

Showing all 4 results

Ürünler

Structure
Multi-core, fine multi-wire copper conductor, special synthetic insulation, special filling layer, special synthetic outer sheath, flame retardant, halogen-free energy cables.

Technical Information
– Manufactured in accordance with TSE 13751.
– Permissible operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– Conductor Structure: Flexible
– LS (Low Smoke) Test: IEC 61034 -1/2
– Burning Droplet Test: IEC 60332-1-3
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-1-2 and IEC 60332-3-24 Cat.C
– CPR (Construction Materials Directive) Test: EN 50399

Areas of Use
They are used in facilities with a fire risk such as hotels, hospitals, shopping malls, power plants and data processing centers, and in facilities where there are many people and valuable devices where mass transportation is carried out by rail systems. These cables do not transmit flame during a fire, do not create a dense smoke layer and do not create an environment suitable for corrosion, thus ensuring the safety of life and property.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
Single-core, single-wire, multi-wire or fine multi-wire copper conductor, special synthetic insulation, flame retardant and halogen-free energy cables.

Technical Information
– Manufactured in accordance with TS EN 50525-3-31.
– Permissible operating temperature: 70 ºC
– Maximum Short Circuit Temperature: 160 ºC
– Conductor Structure: Flexible
– LS (Low Smoke) Test: IEC 61034 -1/2
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-1-2
– CPR (Construction Materials Directive) Test: EN 60332-1-2

Places of Use
They are used as lighting and installation cables in dry spaces, switchgear facilities, distribution systems, and businesses.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file, or send it to the address you want via e-mail.

Structure
Single-core, single-wire, multi-wire or fine multi-wire copper conductor, special synthetic insulation, flame retardant and halogen-free energy cables.

Technical Information
– Manufactured in accordance with TS EN 50525-3-31.
– Permissible operating temperature: 70 ºC
– Maximum Short Circuit Temperature: 160 ºC
– Conductor Structure: Flexible
– LS (Low Smoke) Test: IEC 61034 -1/2
– Burning Droplet Test: IEC 60332-1-3
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-1-2 and IEC 60332-3-24 Cat.C
– CPR (Construction Materials Directive) Test: EN 50399

Places of Use
They are used as lighting and installation cables in dry spaces, switchgear facilities, distribution systems, and businesses.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
Single-core, single-wire, multi-wire or fine multi-wire copper conductor, special synthetic insulation, flame retardant and halogen-free energy cables.

Technical Information
– Manufactured in accordance with TS EN 50525-3-31.
– Permissible operating temperature: 70 ºC
– Maximum Short Circuit Temperature: 160 ºC
– Conductor Structure: Flexible
– LS (Low Smoke) Test: IEC 61034 -1/2
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-1-2
– CPR (Construction Materials Directive) Test: EN 60332-1-2

Areas of Use
They are used as lighting and installation cables in dry spaces, switchgear facilities, distribution systems, and businesses.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file, or send it to the address you want via e-mail.