You are here:

Showing all 5 results

Ürünler

Structure
Multi-core, finely stranded, copper conductor, PROTODUR® (PVC) insulated, PROTODUR® (PVC) outer sheathed, flexible cables.

Technical Information
– Manufactured according to TS EN 50525-2-11.
– Permissible Operating Temperature: 70 ºC
– Maximum Short Circuit Temperature: 160 ºC
– Conductor Structure: Flexible
– FR (Flame Resistance) Test: IEC 60332-1-2
– CPR (Construction Materials Directive) Test: EN 60332-1-2
– Test Voltage (AC): 1.5 kV

Areas of Use
They are used as mobile connection cables in closed and dry places where mechanical stresses are low.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
Single-core, finely stranded, copper conductor PROTODUR® (PVC) insulated flexible cables.

Technical Information
– Manufactured according to TS EN 50525-2-31.
– Permissible Operating Temperature: 70 ºC
– Maximum Short Circuit Temperature: 160 ºC
– Conductor Structure: Flexible
– FR (Flame Resistance) Test: IEC 60332-1-2
– CPR (Construction Materials Directive) Test: EN 60332-1-2
– Test Voltage (AC): 2 kV-2.5 kV

Areas of Use
They are used in the internal installations of panels and electrical devices, under plaster or in pipes on plaster.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
Single-core, single or multi-wire, copper conductor PROTODUR® (PVC) insulated cables.

Technical Information
– Manufactured according to TS EN 50525-2-31.
– Permissible Operating Temperature: 70 ºC
– Maximum Short Circuit Temperature: 160 ºC
– Conductor Structure: Rigid
– FR (Flame Resistance) Test: IEC 60332-1-2
– CPR (Construction Materials Directive) Test: EN 60332-1-2
– Test Voltage (AC): 2 kV-2.5 kV

Areas of Use
They are used in closed, dry places, fixed installations, distribution panels, under plaster and on plaster inside pipes, on hooks.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
Multi-core, finely stranded, copper conductor PROTODUR® (PVC) insulated, PROTODUR® (PVC) outer sheathed, flexible cables.

Technical Information
– Manufactured according to TS EN 50525-2-11.
– Permissible Operating Temperature: 70 ºC
– Maximum Short Circuit Temperature: 160 ºC
– Conductor Structure: Flexible
– FR (Flame Resistance) Test: IEC 60332-1-2
– CPR (Construction Materials Directive) Test: EN 60332-1-2
– Test Voltage (AC): 2 kV

Areas of Use
They are used in closed and dry places where mechanical stresses are present, in household appliances, in steamy and humid places.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
Multi-core, solid or stranded, copper conductor, PROTODUR® (PVC) insulated, PROTODUR® (PVC) outer sheathed antigron cables.

Technical Information
– Manufactured according to TS HD 21.4 S2.
– Permissible Operating Temperature: 70 ºC
– Maximum Short Circuit Temperature: 160 ºC
– Conductor Structure: Rigid
– FR (Flame Resistance) Test: IEC 60332-1-2
– CPR (Construction Materials Directive) Test: EN 60332-1-2
– Test Voltage (AC): 2 kV

Areas of Use
They are used in dry, humid and wet places, in workshops, factories and all kinds of workplaces and warehouses with fire and explosion risks, outdoors, they are not laid underground, they are used fixedly in pipes, on plaster and under plaster.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.