You are here:

Showing 1–16 of 27 results

Ürünler

Structure
Single-core, single-wire or fine multi-wire, copper conductor, silicone rubber insulated, flexible cables resistant to high ambient temperatures -40 ºC, +180 ºC operating temperature.

Technical Information
– Manufactured in accordance with TSE K 332.
– Minimum allowed operating temperature: -40 ºC
– Maximum allowed operating temperature: 180 ºC
– Maximum Short Circuit Temperature: 350 ºC
– FR (Flame Resistance) Test: IEC 60332-1-2
– Conductor Structure: Flexible

Areas of Use
They are used in dry, humid and wet places where there is high ambient temperature and low mechanical stress, as internal and external flexible connection cables at continuous 180 ºC temperature and short-term 350 ºC temperature.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
Single-core, tinned finely stranded copper conductor; EPR insulation, PCP rubber outer sheath.

Technical Information
– Manufactured in accordance with VDE 0250-602.
– Permissible operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 200 ºC
– Conductor Structure: Flexible
– FR (Flame Resistance) Test: IEC 60332-1-2 and IEC 60332-3-24 Cat.C

Areas of Use
Used in trains and buses, in continuously operating installations, in pipes and closed installation channels and in mobile connections. Also used in short circuit and grounding connections.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
Tinned, very fine and multi-wire, copper conductor, PROTOLON® (EPR) insulated, rubber inner sheath, synthetic yarn sock braid, tear-resistant, chloroprene-rubber outer sheathed crane control cables.

Technical Information
– Manufactured in accordance with TSE K 371.
– Permissible operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– Conductor Structure: Flexible
– FR (Flame Resistance) Test: IEC 60332-1-2 and IEC 60332-3-24 Cat.C
– Maximum Movement Speed: 120 m/min
– Continuous Tensile Force: 20 N/mm2

Areas of Use
They are used in dry, damp and wet areas, in places where there are external, heavy mechanical strains, in cranes and similar work machines with a maximum winding speed of 120 m/min.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
Tinned, finely stranded electrolytic copper conductor, PROTOLON® (EPR) insulation, electrical field homogenizing inner and outer rubber semiconductor layer, PROTOFIRM® outer sheathed oil and flame resistant medium voltage tail cables.

Technical Information
– Manufactured in accordance with TSE K 371.
– Permissible operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 200 ºC
– Conductor Structure: Flexible
– FR (Flame Resistance) Test: IEC 60332-1-2
– Suitable for use in oily environments.
– Continuous Tensile Strength: 15 N/mm2

Areas of Use
They are used in dry, damp and wet areas, outside, open mines, in businesses where resistance to friction is required, inside tunnels, in quarries, in places where there are heavy mechanical strains.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
Tinned, finely stranded copper conductor, PROTOLON® (EPR) insulation, electrical field homogenizing rubber inner and outer semi-conducting layer, rubber inner sheath, synthetic yarn braid, PROTOFIRM® outer sheath oil and flame resistant medium voltage cables.

Technical Information
– Manufactured in accordance with TSE K 371.
– Permissible operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 200 ºC
– FR (Flame Resistance) Test: IEC 60332-1-2
– Suitable for use in oily environments.
– Maximum Movement Speed: 120 m/min
– Continuous Tensile Force: 15 N/mm2

Areas of Use
They are used as tail cables and feeder cables in dry, damp and wet areas, in places with external, heavy mechanical strain, in mines, in conveyor and transfer roller belt systems, in cranes and similar work machines.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
Tinned, finely stranded, electrolytic copper conductor, PROTOLON® (EPR) insulation, rubber filler element, rubber inner sheath and tear-resistant PROTOFIRM® outer sheathed tail cables.

Technical Information
– Manufactured in accordance with TSE K 371.
– Permissible operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 200 ºC
– Conductor Structure: Flexible
– FR (Flame Resistance) Test: IEC 60332-1-2 and IEC 60332-3-24 Cat.C
– Maximum Movement Speed: 60 m/min
– Continuous Tensile Strength: 15 N/mm2

Areas of Use
They are used in dry, damp and wet areas, in places with external, heavy mechanical stresses, in mines, in conveyor and conveyor roller belt systems, in cranes and similar work machines as tail cables and feeder cables.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
Multi-core, multi-wire copper conductor, special XLPE insulation, special synthetic outer sheath, flame retardant, halogen-free, rubber filled, copper wire braided, ship cables that continue their function for 180 minutes under fire.

Technical Information
– Manufactured in accordance with IEC 60092-350/375/376.
– Minimum allowed operating temperature: -15 ºC
– Maximum allowed operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– LS (Low Smoke) Test: IEC 61034 -1/2
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-3-22 Cat.A
– FE (Current Conduction) Test: IEC 60331-21

Areas of Use
They are used as communication, signal and control cables in fixed installations in places where mechanical and electrical protection is required on ships and all kinds of marine vehicles.

Structure
Multi-core, multi-wire copper conductor, double twisted, special XLPE insulation, special synthetic outer sheath, flame retardant, halogen-free, rubber filled, copper wire braided ship cables that do not create a dense smoke layer during fire.

Technical Information
– Manufactured in accordance with IEC 60092-350/375/376.
– Minimum allowed operating temperature: -15 ºC
– Maximum allowed operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– LS (Low Smoke) Test: IEC 61034 -1/2
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-3-22 Cat.A
– Suitable for use in oily environments.

Areas of Use
They are used as communication, signal and control cables in fixed installations in places where mechanical and electrical protection is required on ships and all kinds of marine vehicles.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
Multi-core, multi-wire or compressed multi-wire copper conductor, special XLPE insulation, special synthetic outer sheath, flame retardant, halogen-free, rubber-filled, copper wire braided, ship cables that continue their function for 180 minutes under fire.

Technical Information
– Manufactured in accordance with IEC 60092-350/353.
– Minimum allowed operating temperature: -15 ºC
– Maximum allowed operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– LS (Low Smoke) Test: IEC 61034 -1/2
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-3-22 Cat.A
– FE (Current Conduction) Test: IEC 60331-21

Areas of Use
They are used as energy and control cables in ships and all kinds of marine vehicles, on decks, in dry, wet and steamy areas, in fixed installations where mechanical and electrical protection is required, in security, alarm and other critical systems. They are manufactured to continue their functions under fire.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
Single or multi-core, multi-wire or compressed multi-wire copper conductor, special halogen-free XLPE insulation, special synthetic outer sheath, flame retardant, halogen-free, rubber-filled, copper wire braided ship cables that do not create a dense smoke layer in the event of a fire.

Technical Information
– Manufactured in accordance with IEC 60092-350/353.
– Minimum allowed operating temperature: -15 ºC
– Maximum allowed operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– LS (Low Smoke) Test: IEC 61034 -1/2
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-3-22 Cat.A
– Suitable for use in oily environments.

Places of Use
They are used as energy and control cables in fixed installations where mechanical and electrical protection is required on ships and marine vehicles, in security, alarm and other critical systems.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
Multi-core, finely stranded copper conductor, special halogen-free XLPE insulation, special synthetic outer sheath, flame retardant, halogen-free, non-smoking rubber-filled, copper wire braided ship cables.

Technical Information
– Manufactured in accordance with IEC 60092-350/353.
– Minimum allowed operating temperature: -15 ºC
– Maximum allowed operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– LS (Low Smoke) Test: IEC 61034 -1/2
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-3-22 Cat.A
– Suitable for use in oily environments.

Areas of Use
They are used as energy and control cables in fixed installations, security, alarm and other critical systems where mechanical and electrical protection is required on ships and marine vehicles.

Structure
Single or multi-core, fine multi-wire copper conductor, special halogen-free XLPE insulation, special synthetic outer sheath, flame retardant, halogen-free, ship cables that do not create dense smoke during fire.

Technical Information
– Manufactured in accordance with IEC 60092-350/353.
– Minimum allowed operating temperature: -15 ºC
– Maximum allowed operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– LS (Low Smoke) Test: IEC 61034 -1/2
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-3-22 Cat.A
– Suitable for use in oily environments.

Areas of Use
They are used as energy and control cables in fixed installations, under decks, dry, wet and steamy areas on ships and all kinds of marine vehicles.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
Multi-core, multi-wire copper conductor, special halogen-free XLPE insulation, special synthetic outer sheath, flame retardant, halogen-free, ship cables that do not create dense smoke during fire.

Technical Information
– Manufactured in accordance with IEC 60092-350/353.
– Minimum allowed operating temperature: -15 ºC
– Maximum allowed operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– LS (Low Smoke) Test: IEC 61034 -1/2
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-3-22 Cat.A
– Suitable for use in oily environments.

Areas of Use
They are used as energy and control cables in fixed installations, under decks, dry, wet and steamy areas on ships and all kinds of marine vehicles.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
Multi-core, finely stranded, copper conductor, HEPR insulated, PROTODUR (PVC) outer sheathed energy cables.

Technical Information
– Manufactured in accordance with TS IEC 60502-1.
– Permissible operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC (Short circuit time t ≤ 5 sec.)
– Conductor Structure: Flexible
– FR (Flame Resistance) Test: IEC 60332-1-2 and IEC 60332-3-24 Cat.C
– Test Voltage (AC): 3.5 kV

Areas of Use
Used in applications requiring flexibility outdoors, in cable ducts, and underground as energy, network and lighting cables.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
Finely stranded copper conductor, HEPR insulated, PROTODUR (PVC) outer sheathed energy cables.

Technical Information
– Manufactured in accordance with TS IEC 60502-1.
– Permissible operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC (Short circuit time t ≤ 5 sec.)
– Conductor Structure: Flexible
– FR (Flame Resistance) Test: IEC 60332-1-2 and IEC 60332-3-24 Cat.C
– Test Voltage (AC): 3.5 kV

Areas of Use
Used in applications requiring flexibility outdoors, in cable ducts, and underground as energy, network and lighting cables.

Structure
Single-core, finely stranded, copper conductor, HEPR insulated, PROTODUR (PVC) outer sheathed energy cables.

Technical Information
– Manufactured in accordance with TS IEC 60502-1.
– Permissible operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC (Short circuit time t ≤ 5 sec.)
– Conductor Structure: Flexible
– FR (Flame Resistance) Test: IEC 60332-1-2 and IEC 60332-3-24 Cat.C
– Test Voltage (AC): 3.5 kV

Places of Use
Used as energy, network and lighting cables in open areas, in cable ducts, and underground applications requiring flexibility.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.