You are here:

Showing all 7 results

Ürünler

Structure
Multi-core, multi-wire copper conductor, special XLPE insulation, special synthetic outer sheath, flame retardant, halogen-free, rubber filled, copper wire braided, ship cables that continue their function for 180 minutes under fire.

Technical Information
– Manufactured in accordance with IEC 60092-350/375/376.
– Minimum allowed operating temperature: -15 ºC
– Maximum allowed operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– LS (Low Smoke) Test: IEC 61034 -1/2
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-3-22 Cat.A
– FE (Current Conduction) Test: IEC 60331-21

Areas of Use
They are used as communication, signal and control cables in fixed installations in places where mechanical and electrical protection is required on ships and all kinds of marine vehicles.

Structure
Multi-core, multi-wire copper conductor, double twisted, special XLPE insulation, special synthetic outer sheath, flame retardant, halogen-free, rubber filled, copper wire braided ship cables that do not create a dense smoke layer during fire.

Technical Information
– Manufactured in accordance with IEC 60092-350/375/376.
– Minimum allowed operating temperature: -15 ºC
– Maximum allowed operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– LS (Low Smoke) Test: IEC 61034 -1/2
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-3-22 Cat.A
– Suitable for use in oily environments.

Areas of Use
They are used as communication, signal and control cables in fixed installations in places where mechanical and electrical protection is required on ships and all kinds of marine vehicles.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
Multi-core, multi-wire or compressed multi-wire copper conductor, special XLPE insulation, special synthetic outer sheath, flame retardant, halogen-free, rubber-filled, copper wire braided, ship cables that continue their function for 180 minutes under fire.

Technical Information
– Manufactured in accordance with IEC 60092-350/353.
– Minimum allowed operating temperature: -15 ºC
– Maximum allowed operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– LS (Low Smoke) Test: IEC 61034 -1/2
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-3-22 Cat.A
– FE (Current Conduction) Test: IEC 60331-21

Areas of Use
They are used as energy and control cables in ships and all kinds of marine vehicles, on decks, in dry, wet and steamy areas, in fixed installations where mechanical and electrical protection is required, in security, alarm and other critical systems. They are manufactured to continue their functions under fire.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
Single or multi-core, multi-wire or compressed multi-wire copper conductor, special halogen-free XLPE insulation, special synthetic outer sheath, flame retardant, halogen-free, rubber-filled, copper wire braided ship cables that do not create a dense smoke layer in the event of a fire.

Technical Information
– Manufactured in accordance with IEC 60092-350/353.
– Minimum allowed operating temperature: -15 ºC
– Maximum allowed operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– LS (Low Smoke) Test: IEC 61034 -1/2
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-3-22 Cat.A
– Suitable for use in oily environments.

Places of Use
They are used as energy and control cables in fixed installations where mechanical and electrical protection is required on ships and marine vehicles, in security, alarm and other critical systems.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
Multi-core, finely stranded copper conductor, special halogen-free XLPE insulation, special synthetic outer sheath, flame retardant, halogen-free, non-smoking rubber-filled, copper wire braided ship cables.

Technical Information
– Manufactured in accordance with IEC 60092-350/353.
– Minimum allowed operating temperature: -15 ºC
– Maximum allowed operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– LS (Low Smoke) Test: IEC 61034 -1/2
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-3-22 Cat.A
– Suitable for use in oily environments.

Areas of Use
They are used as energy and control cables in fixed installations, security, alarm and other critical systems where mechanical and electrical protection is required on ships and marine vehicles.

Structure
Single or multi-core, fine multi-wire copper conductor, special halogen-free XLPE insulation, special synthetic outer sheath, flame retardant, halogen-free, ship cables that do not create dense smoke during fire.

Technical Information
– Manufactured in accordance with IEC 60092-350/353.
– Minimum allowed operating temperature: -15 ºC
– Maximum allowed operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– LS (Low Smoke) Test: IEC 61034 -1/2
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-3-22 Cat.A
– Suitable for use in oily environments.

Areas of Use
They are used as energy and control cables in fixed installations, under decks, dry, wet and steamy areas on ships and all kinds of marine vehicles.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
Multi-core, multi-wire copper conductor, special halogen-free XLPE insulation, special synthetic outer sheath, flame retardant, halogen-free, ship cables that do not create dense smoke during fire.

Technical Information
– Manufactured in accordance with IEC 60092-350/353.
– Minimum allowed operating temperature: -15 ºC
– Maximum allowed operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– LS (Low Smoke) Test: IEC 61034 -1/2
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-3-22 Cat.A
– Suitable for use in oily environments.

Areas of Use
They are used as energy and control cables in fixed installations, under decks, dry, wet and steamy areas on ships and all kinds of marine vehicles.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.