Structure
Tinned, stranded, copper conductor, PROTOTHEN®-X (XLPE) insulation, metallic copper screen, polyethylene outer sheathed runway lighting primary cables.
Technical Information
– Manufactured in accordance with FAA L824/AC 150/5345-7F.
– Permissible operating temperature: 90 ºC
– Maximum short circuit temperature: 250 ºC
– Conductor structure: Flexible
– FR (flame resistance) test: IEC 60332-1-2
Areas of use
Used underground and externally in airport runway lighting installations and in the connection of direct current regulators to alternating voltage circuits.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Tinned, stranded, copper conductor, EPR insulated, metallic copper screened, PROTOFIRM® outer sheathed primary runway lighting cables.
Technical Information
– Manufactured in accordance with FAA L824/AC 150/5345-7F.
– Permissible operating temperature: 90 ºC
– Maximum short circuit temperature: 250 ºC
– Conductor Structure: Flexible
– FR (Flame Resistance) Test: IEC 60332-1-2
– Suitable for use in oily environments.
Areas of Use
Used underground and externally in airport runway lighting installations and in the connection of direct current regulators to alternating voltage circuits.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Single-core, finely stranded, bare or tinned, layer-spun (A) or twisted (B) copper conductor. Specially blended lead-free PVC insulation.
Technical Information
– Manufactured in accordance with DIN 72551 / ISO 6722.
– Minimum permitted operating temperature: -40 ºC
– Maximum permitted operating temperature: 105 ºC
– Conductor Structure: Flexible
– FR (Flame Resistance) Test: IEC 60332-1-2
– Test Voltage (AC): 1 kV
– Suitable for use in oily environments.
Areas of Use
They are used in various electrical systems of vehicles, automobile interior cabins.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Single-core, finely stranded, bare or tinned copper conductor, special blend lead-free PVC insulated automotive cables
Technical Information
– Manufactured in accordance with ISO 6722.
– Minimum allowed operating temperature: -40 ºC
– Maximum allowed operating temperature: 105 ºC
– Conductor Structure: Flexible
– FR (Flame Resistance) Test: IEC 60332-1-2
– Test Voltage (AC): 1 kV
– Suitable for use in oily environments.
Areas of Use
They are used in various electrical systems of vehicles, in the interior living cabin of automobiles.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Single-core, very thin and multi-wire, copper conductor, flame and oil resistant, rubber outer sheathed flexible welding cables.
Technical Information
– Manufactured in accordance with TS EN 50525-2-81.
– Permissible operating temperature: 85 ºC
– Maximum Short Circuit Temperature: 250 ºC
– Conductor Structure: Flexible
– FR (Flame Resistance) Test: IEC 60332-1-2
– Suitable for use in oily environments.
Places of Use
They are used as power and connection cables in welding machines, in oily and hot environments under all kinds of weather conditions, both internally and externally.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Multi-core, fine multi-wire, copper conductor rubber insulated, flame and oil resistant rubber outer sheathed cables.
Technical Information
– Manufactured in accordance with TS EN 50525-2-21.
– Permissible operating temperature: 60 ºC
– Maximum Short Circuit Temperature: 200 ºC
– Conductor Structure: Flexible
– FR (Flame Resistance) Test: IEC 60332-1-2
– Suitable for use in oily environments.
Areas of Use
They are used in humid places, kitchen appliances such as water heaters, electric stoves, portable workshop devices such as hand drills and hand lamps, places where mechanical effects are low, oily places. These cables are flame resistant according to IEC 60332-1-2.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Multi-core, fine multi-wire, copper conductor, rubber insulated, flame and oil resistant rubber outer sheathed industrial type cables.
Technical Information
– Manufactured in accordance with TS EN 50525-2-21.
– Permissible operating temperature: 60 ºC
– Maximum Short Circuit Temperature: 200 ºC
– Conductor Structure: Flexible
– FR (Flame Resistance) Test: IEC 60332-1-2
– Suitable for use in oily environments.
Areas of Use
They are used in humid places, in kitchen appliances such as water heaters, electric stoves, portable workshop devices such as hand drills and hand lamps, and in places where mechanical effects are low.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Multi-core, finely stranded, electrolytic copper conductor, PROTODUR® (PVC) insulated, core numbered, oil resistant, PROTODUR® (PVC) outer sheathed, flexible measurement and control cables.
Technical Information
– Manufactured in accordance with TS EN 50525-2-51.
– Permissible operating temperature: 70 ºC
– Maximum Short Circuit Temperature: 160 ºC
– Conductor Structure: Flexible
– FR (Flame Resistance) Test: IEC 60332-1-2
– Test Voltage (AC): 2 kV
– Suitable for use in oily environments.
Areas of Use
They are used as measurement and control cables in dry, damp and wet areas, in places where there is no high mechanical stress internally, in machines, mass production lines, control devices, computer systems.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Multi-core, finely stranded, electrolytic copper conductor, PROTODUR® (PVC) insulated, cores numbered, PROTODUR® (PVC) inner sheathed, tinned copper wire braid screened, oil resistant, PROTODUR® (PVC) outer sheathed, flexible measurement and control cables.
Technical Information
– Manufactured in accordance with TS EN 50525-2-51.
– Permissible operating temperature: 70 ºC
– Maximum Short Circuit Temperature: 160 ºC
– Conductor Structure: Flexible
– FR (Flame Resistance) Test: IEC 60332-1-2
– Test Voltage (AC): 2 kV
– Suitable for use in oily environments.
Areas of Use
They are used as measurement and control cables in dry, damp and wet areas where the degree of protection against electromagnetic interference is required, in places where there is no high mechanical stress internally, in machines, mass production lines, control devices, computer systems.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Single or multi-core, fine multi-wire, copper conductor, rubber insulated, rubber outer sheathed oil and flame resistant cables.
Technical Information
– Manufactured in accordance with TS EN 50525-2-21.
– Permissible operating temperature: 60 ºC
– Maximum Short Circuit Temperature: 200 ºC
– Conductor Structure: Flexible
– FR (Flame Resistance) Test: IEC 60332-1-2
– Suitable for use in oily environments.
Areas of Use
They are used in dry and humid places, in open facilities, in heavy conditions, in devices exposed to high mechanical effects, in mobile engines, in electric trains, in agricultural devices and facilities, in clean water facilities.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
Multi-core, fine multi-wire, copper conductor, silicone rubber insulated, flexible cables with operating temperatures of -40 ºC, +180 ºC.
Technical Information
– Manufactured in accordance with VDE 0250e.
– Minimum allowed operating temperature: -40 ºC
– Maximum allowed operating temperature: 180 ºC
– Maximum Short Circuit Temperature: 350 ºC
– Conductor Structure: Flexible
Areas of Use
They are used as internal and external flexible connection cables at continuous 180 ºC and short-term 350 ºC temperatures in dry, humid and wet locations where there is high ambient temperature and low mechanical stress.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.