Ürünler

Structure
Single-core, single-wire or fine multi-wire, copper conductor, silicone rubber insulated, flexible cables resistant to high ambient temperatures -40 ºC, +180 ºC operating temperature.

Technical Information
– Manufactured in accordance with TSE K 332.
– Minimum allowed operating temperature: -40 ºC
– Maximum allowed operating temperature: 180 ºC
– Maximum Short Circuit Temperature: 350 ºC
– FR (Flame Resistance) Test: IEC 60332-1-2
– Conductor Structure: Flexible

Areas of Use
They are used in dry, humid and wet places where there is high ambient temperature and low mechanical stress, as internal and external flexible connection cables at continuous 180 ºC temperature and short-term 350 ºC temperature.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
Single-core, tinned finely stranded copper conductor; EPR insulation, PCP rubber outer sheath.

Technical Information
– Manufactured in accordance with VDE 0250-602.
– Permissible operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 200 ºC
– Conductor Structure: Flexible
– FR (Flame Resistance) Test: IEC 60332-1-2 and IEC 60332-3-24 Cat.C

Areas of Use
Used in trains and buses, in continuously operating installations, in pipes and closed installation channels and in mobile connections. Also used in short circuit and grounding connections.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
Tinned, very fine and multi-wire, copper conductor, PROTOLON® (EPR) insulated, rubber inner sheath, synthetic yarn sock braid, tear-resistant, chloroprene-rubber outer sheathed crane control cables.

Technical Information
– Manufactured in accordance with TSE K 371.
– Permissible operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– Conductor Structure: Flexible
– FR (Flame Resistance) Test: IEC 60332-1-2 and IEC 60332-3-24 Cat.C
– Maximum Movement Speed: 120 m/min
– Continuous Tensile Force: 20 N/mm2

Areas of Use
They are used in dry, damp and wet areas, in places where there are external, heavy mechanical strains, in cranes and similar work machines with a maximum winding speed of 120 m/min.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
Tinned, finely stranded electrolytic copper conductor, PROTOLON® (EPR) insulation, electrical field homogenizing inner and outer rubber semiconductor layer, PROTOFIRM® outer sheathed oil and flame resistant medium voltage tail cables.

Technical Information
– Manufactured in accordance with TSE K 371.
– Permissible operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 200 ºC
– Conductor Structure: Flexible
– FR (Flame Resistance) Test: IEC 60332-1-2
– Suitable for use in oily environments.
– Continuous Tensile Strength: 15 N/mm2

Areas of Use
They are used in dry, damp and wet areas, outside, open mines, in businesses where resistance to friction is required, inside tunnels, in quarries, in places where there are heavy mechanical strains.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
Tinned, finely stranded copper conductor, PROTOLON® (EPR) insulation, electrical field homogenizing rubber inner and outer semi-conducting layer, rubber inner sheath, synthetic yarn braid, PROTOFIRM® outer sheath oil and flame resistant medium voltage cables.

Technical Information
– Manufactured in accordance with TSE K 371.
– Permissible operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 200 ºC
– FR (Flame Resistance) Test: IEC 60332-1-2
– Suitable for use in oily environments.
– Maximum Movement Speed: 120 m/min
– Continuous Tensile Force: 15 N/mm2

Areas of Use
They are used as tail cables and feeder cables in dry, damp and wet areas, in places with external, heavy mechanical strain, in mines, in conveyor and transfer roller belt systems, in cranes and similar work machines.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
Tinned, finely stranded, electrolytic copper conductor, PROTOLON® (EPR) insulation, rubber filler element, rubber inner sheath and tear-resistant PROTOFIRM® outer sheathed tail cables.

Technical Information
– Manufactured in accordance with TSE K 371.
– Permissible operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 200 ºC
– Conductor Structure: Flexible
– FR (Flame Resistance) Test: IEC 60332-1-2 and IEC 60332-3-24 Cat.C
– Maximum Movement Speed: 60 m/min
– Continuous Tensile Strength: 15 N/mm2

Areas of Use
They are used in dry, damp and wet areas, in places with external, heavy mechanical stresses, in mines, in conveyor and conveyor roller belt systems, in cranes and similar work machines as tail cables and feeder cables.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
Multi-core, finely stranded, copper conductor, HEPR insulated, PROTODUR (PVC) outer sheathed energy cables.

Technical Information
– Manufactured in accordance with TS IEC 60502-1.
– Permissible operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC (Short circuit time t ≤ 5 sec.)
– Conductor Structure: Flexible
– FR (Flame Resistance) Test: IEC 60332-1-2 and IEC 60332-3-24 Cat.C
– Test Voltage (AC): 3.5 kV

Areas of Use
Used in applications requiring flexibility outdoors, in cable ducts, and underground as energy, network and lighting cables.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
Finely stranded copper conductor, HEPR insulated, PROTODUR (PVC) outer sheathed energy cables.

Technical Information
– Manufactured in accordance with TS IEC 60502-1.
– Permissible operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC (Short circuit time t ≤ 5 sec.)
– Conductor Structure: Flexible
– FR (Flame Resistance) Test: IEC 60332-1-2 and IEC 60332-3-24 Cat.C
– Test Voltage (AC): 3.5 kV

Areas of Use
Used in applications requiring flexibility outdoors, in cable ducts, and underground as energy, network and lighting cables.

Structure
Single-core, finely stranded, copper conductor, HEPR insulated, PROTODUR (PVC) outer sheathed energy cables.

Technical Information
– Manufactured in accordance with TS IEC 60502-1.
– Permissible operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC (Short circuit time t ≤ 5 sec.)
– Conductor Structure: Flexible
– FR (Flame Resistance) Test: IEC 60332-1-2 and IEC 60332-3-24 Cat.C
– Test Voltage (AC): 3.5 kV

Places of Use
Used as energy, network and lighting cables in open areas, in cable ducts, and underground applications requiring flexibility.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
Single-core, very thin and multi-wire, copper conductor, flame and oil resistant, rubber outer sheathed flexible welding cables.

Technical Information
– Manufactured in accordance with TS EN 50525-2-81.
– Permissible operating temperature: 85 ºC
– Maximum Short Circuit Temperature: 250 ºC
– Conductor Structure: Flexible
– FR (Flame Resistance) Test: IEC 60332-1-2
– Suitable for use in oily environments.

Places of Use
They are used as power and connection cables in welding machines, in oily and hot environments under all kinds of weather conditions, both internally and externally.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
Multi-core, fine multi-wire, copper conductor rubber insulated, flame and oil resistant rubber outer sheathed cables.

Technical Information
– Manufactured in accordance with TS EN 50525-2-21.
– Permissible operating temperature: 60 ºC
– Maximum Short Circuit Temperature: 200 ºC
– Conductor Structure: Flexible
– FR (Flame Resistance) Test: IEC 60332-1-2
– Suitable for use in oily environments.

Areas of Use
They are used in humid places, kitchen appliances such as water heaters, electric stoves, portable workshop devices such as hand drills and hand lamps, places where mechanical effects are low, oily places. These cables are flame resistant according to IEC 60332-1-2.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
Multi-core, fine multi-wire, copper conductor, rubber insulated, flame and oil resistant rubber outer sheathed industrial type cables.

Technical Information
– Manufactured in accordance with TS EN 50525-2-21.
– Permissible operating temperature: 60 ºC
– Maximum Short Circuit Temperature: 200 ºC
– Conductor Structure: Flexible
– FR (Flame Resistance) Test: IEC 60332-1-2
– Suitable for use in oily environments.

Areas of Use
They are used in humid places, in kitchen appliances such as water heaters, electric stoves, portable workshop devices such as hand drills and hand lamps, and in places where mechanical effects are low.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
Single or multi-core, fine multi-wire, copper conductor, rubber insulated, rubber outer sheathed oil and flame resistant cables.

Technical Information
– Manufactured in accordance with TS EN 50525-2-21.
– Permissible operating temperature: 60 ºC
– Maximum Short Circuit Temperature: 200 ºC
– Conductor Structure: Flexible
– FR (Flame Resistance) Test: IEC 60332-1-2
– Suitable for use in oily environments.

Areas of Use
They are used in dry and humid places, in open facilities, in heavy conditions, in devices exposed to high mechanical effects, in mobile engines, in electric trains, in agricultural devices and facilities, in clean water facilities.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
Multi-core, fine multi-wire, copper conductor, silicone rubber insulated, flexible cables with operating temperatures of -40 ºC, +180 ºC.

Technical Information
– Manufactured in accordance with VDE 0250e.
– Minimum allowed operating temperature: -40 ºC
– Maximum allowed operating temperature: 180 ºC
– Maximum Short Circuit Temperature: 350 ºC
– Conductor Structure: Flexible

Areas of Use
They are used as internal and external flexible connection cables at continuous 180 ºC and short-term 350 ºC temperatures in dry, humid and wet locations where there is high ambient temperature and low mechanical stress.