Structure
The cable core is formed by twisting LSOH insulated cores or pairs with a thickness that will meet the electrical properties onto the conductor formed by multiple twisting of copper wires. After wrapping a polyester tape (optional) with a holding and protective feature onto this core, a longitudinal earth wire and 1 layer of aluminum-coated polyester tape screen with the metal part facing inward are wrapped onto it to ensure the continuity of the screen. A gray LSOH sheath is coated onto the screen. The outer sheath thickness shall be in accordance with ÜBM-03-BK-022.
Technical Information
Temperature in fixed conditions: -30 °C, +70 °C
Temperature in moving conditions: -5 °C, +50 °C
Areas of Use
Used in indoor automation systems, in dry environments with protection against electrical interactions, in electronic control systems, as a signal and information communication cable with halogen-free and flame-retardant properties
You can view the details by clicking on the PDF icon for product technical specifications and details, download the file or send it to the address you want via e-mail.
Structure
A flame barrier mica tape is helically wrapped on the conductor made of copper wire. The cable core is formed by twisting the cores or pairs coated with LSOH insulation on the mica tape conductors, which are thick enough to meet the electrical specifications. After wrapping a polyester tape (optional) with a holding and protective feature on this core, a longitudinal earth wire and 1 layer of aluminum-coated polyester tape screen with the metal part turned inward are wrapped on top to ensure the continuity of the screen. The orange-colored LSOH sheath is coated on the screen.
Technical Information
Temperature in fixed conditions: -30 °C, +70 °C
Temperature in mobile conditions: -5 °C, +50 °C
Areas of Use
It is used as a halogen-free and flame-retardant signal communication cable protected against electrical interference in fixed installations inside buildings.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
The cable core is formed by twisting cores or pairs coated with LSOH insulation, with a thickness that will meet the electrical properties, onto the conductor formed by multiple twisting of copper wires. After wrapping a polyester tape with holding and protective properties and a braided screen consisting of tinned copper wires (Min. Coating 50%) on this core, a gray LSOH sheath is coated. The outer sheath thickness shall be in accordance with ÜBM-03-BK-022
Technical Information
Temperature in fixed conditions: -30 °C, +70 °C
Temperature in mobile conditions: -5 °C, +50 °C
Areas of Use
It is used as a signal and information communication cable with halogen-free and flame-retardant properties in indoor automation systems, electronic control systems, and dry environments.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
A flame barrier mica tape is helically wrapped on the conductor made of copper wire. The cable core is formed by twisting the cores or pairs coated with LSOH insulation on the mica tape conductors, which are thick enough to meet the electrical properties. After wrapping a polyester tape with holding and protective properties on this core and a braided screen made of tinned copper wires (min. 50% coating), an orange colored LSOH sheath is covered. The outer sheath thickness shall be in accordance with TSE K 178.
Technical Information
Temperature in fixed conditions: -30 °C, +70 °C
Temperature in mobile conditions: -5 °C, +50 °C
Areas of Use
It is used as a signal and information communication cable with halogen-free and flame-retardant properties in indoor automation systems, electronic control systems, and dry environments.
Structure
The cable core is formed by twisting the cores or pairs coated with LSOH insulation, with a thickness that will meet the electrical properties, onto the conductor formed by multiple twisting of copper wires. After wrapping a polyester tape (optional) with holding and protective properties onto this core, a gray LSOH sheath is coated on it. The outer sheath thickness shall be in accordance with ÜBM-03-BK-022.
Technical Information
Temperature in fixed conditions: -30 °C, +70 °C
Temperature in mobile conditions: -5 °C, +50 °C
Areas of Use
Used as a signal and information communication cable with halogen-free and flame-retardant properties in indoor automation systems, electronic control systems, and dry environments.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
A flame barrier mica tape is helically wrapped on the conductor made of copper wire. The cable core is formed by twisting the cores or pairs coated with LSOH insulation on the mica tape conductors, which are thick enough to meet the electrical specifications. After wrapping a polyester tape (optional) with holding and protective properties on this core, an orange colored LSOH sheath is coated on it. The outer sheath thickness shall be in accordance with TSE K 178.
Technical Information
Temperature in fixed conditions: -30 °C, +70 °C
Temperature in mobile conditions: -5 °C, +50 °C
Areas of Use
It is used as a halogen-free and flame-retardant signal and information communication cable in indoor automation systems, electronic control systems, and dry environments.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
The cable core is formed by twisting PVC insulated cores or pairs with a thickness that will meet the electrical properties onto the conductor formed by multiple twisting of copper wires. After wrapping a holding and protective polyester tape (optional) onto this core, a longitudinal earth wire and 1 layer of aluminum-coated polyester tape screen with the metal part facing inward are wrapped on top to ensure the continuity of the screen. A gray PVC sheath is coated on the screen. The outer sheath thickness shall be in accordance with ÜBM-03-BK-022.
Technical Information
Temperature in fixed conditions: -30 °C, +70 °C
Temperature in mobile conditions: -5 °C, +50 °C
Areas of Use
Used as signal and information communication cable in indoor automation systems, dry environments.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
The cable core is formed by twisting the cores or pairs coated with PVC insulation, with a thickness that will meet the electrical properties, onto the conductor formed by multiple twisting of copper wires. After wrapping a polyester tape with holding and protective properties on this core and a braided screen (Min. coating 50%) consisting of tinned copper wires on it, a gray PVC sheath is covered.
The outer sheath thickness shall be in accordance with ÜBM-03-BK-022.
Technical Information
Temperature in fixed conditions: -30 °C, +70 °C
Temperature in mobile conditions: -5 °C, +50 °C
Areas of Use
It is used in indoor automation systems, electronic control systems, dry environments, as a signal and information communication cable.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.
Structure
A cable core is formed by twisting the cores or pairs coated with PVC insulation in accordance with VDE 0207 Part 4 YI3, with a thickness that will meet the electrical properties, on the conductor formed by multiple twisting of copper wires.
After wrapping a polyester tape (optional) with holding and protective properties on this core, a gray sheath in accordance with VDE 0207 Part 5 YM1 is covered on it.
The outer sheath thickness shall be in accordance with ÜBM-03-BK-022
Technical Information
Temperature in fixed conditions: -30 °C, +70 °C
Temperature in mobile conditions: -5 °C, +50 °C
Areas of Use
Used in indoor automation systems, electronic control systems, dry environments, as signal and information communication cable.
For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.